BUFFALO, NY —
OSHA Inspection: TRC CONTRACTING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRC CONTRACTING LLC in 301 14TH STREET, BUFFALO, NY 14213 (NAICS 238160). OSHA activity number 348335258.
Where did this inspection happen?
- Establishment
- TRC CONTRACTING LLC
- Site address
- 301 14TH STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14213
- Mailing
- 48 DASH STREET, BUFFALO, NY 14220
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Penalty
- Initial $3547.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 6/18/2025 at a roof project located at 301 14th Street, Buffalo, New York; employees were replacing the roof of a three story building. The roof had an 5 in 12 pitch and an eave height of approximately 30 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1750
- — Z (S) $3547
1926.1053 B01
- Issued
- Penalty
- Initial $3547.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 6/18/2025 at a roof project located at 301 14th Street, Buffalo, New York; employees were replacing the roof of a three story building. Employees were accessing the roof with an extension ladders and the side rails of the ladder did not extend 3 feet above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1750
- — Z (S) $3547
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348335258.