Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: KB SIDING & ROOFING CONSTRUCTION LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of KB SIDING & ROOFING CONSTRUCTION LLC in 40016 HIGHWAY P, VANDALIA, MO 63382 (NAICS 238170). OSHA activity number 348363300.

Watch KB Siding & Roofing Construction LLC — free Get an email when a new federal OSHA severe-injury report for KB Siding & Roofing Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
40016 HIGHWAY P
City
VANDALIA
State
MO
ZIP
63382
Mailing
3218 COLES AVENUE, BRECKENRIDGE HILLS, MO 63114
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.50 C

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $3972.00
29 CFR  1926.50(c): At this job site, the employer did not have a person who was certified in first aid training (which includes Basic First Aid and CPR) available to render first aid.   On 06 July 2025, (3) three employees were exposed to an electrical hazard while repositioning two portable aluminum extension ladders, which were lashed together approximately 38 feet in height, at 40016 Highway P in Vandalia, Missouri. The employer did not ensure that a person who was certified in first aid training who was also available to render first aid was made available to employees. Two employees received an electric shock and one employee was electrocuted when the two lashed together portable aluminum ladders the employees were repositioning contacted an energized overhead high voltage powerline.
Recent events (1)
  • — Z (S) $3972

1926.416 A03

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $3972.00
29 CFR 1926.416(a)(3): The employer began work without determining if employees could contact any part of an energized circuit and did not post warning signs and advise employees of the location of the circuit, hazards, and protective measures they need to take:  On 06 July 2025, (3) three employees were exposed to an electrical hazard while repositioning two portable aluminum extension ladders lashed together approximately 38 feet in height, at 40016 Highway P in Vandalia, Missouri. The employer did not determine if employees could contact energized overhead powerlines, did not post warning signs, and did not advise the employees of the location of the energized overhead powerlines. The employees were not made aware of a 7,200 volt three phase overhead power distribution line.
Recent events (1)
  • — Z (S) $3972

1926.1053 A07

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $3972.00
29 CFR 1926.1053(a)(7): Ladders not designed for such use were tied or fastened together to provide longer sections:  On 06 July 2025, (3) three employees were exposed to an electrical hazard while repositioning two portable aluminum extension ladders lashed together approximately 38 feet in height, at 40016 Highway P in Vandalia, Missouri. The ladders were not designed to be fastened together to provide longer sections. Two employees received an electric shock and one employee was electrocuted when the two attached portable aluminum ladders the employees were repositioning contacted an energized overhead high voltage powerline.
Recent events (1)
  • — Z (S) $3972

1926.1060 A

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $3972.00
29 CFR 1926.1060(a): The employer did not provide an adequate training program for each employee using ladders, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders:  On 06 July 2025, (3) three employees were exposed to an electrical hazard while repositioning two portable aluminum extension ladders lashed together approximately 38 feet in height, at 40016 Highway P in Vandalia, Missouri. The employer did not provide adequate ladder training to the employees related to appropriate ladder usage procedures to be followed and associated electrical hazards at the jobsite. Two employees received an electric shock and one employee was electrocuted when the two attached portable aluminum ladders the employees were repositioning contacted an energized overhead high voltage powerline.
Recent events (1)
  • — Z (S) $3972

1904.39 A01

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $2838.00 · Current $2838.00
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident:  On 06 July 2025, a fatality occurred while employees were repositioning lashed ladders which made contact with an overhead powerline, at 40016 Highway P in Vandalia, Missouri. The fatality was reported to OSHA on 08 July 2025, by the Audrain County Sheriffs office and OSHA was not notified prior to 08 July 2025.
Recent events (1)
  • — Z (O) $2838