OSHA Inspection: THE PITTSBURGH PAINT CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE PITTSBURGH PAINT CO. in 4261 WEST WHITE ROAD, OAKWOOD, GA 30566 (NAICS 325510). OSHA activity number 348375353.

Watch THE Pittsburgh Paint CO. — free Get an email when a new federal OSHA severe-injury report for THE Pittsburgh Paint CO. is published. One employer, no account, unsubscribe in one click.
Site address
4261 WEST WHITE ROAD
City
OAKWOOD
State
GA
ZIP
30566
Mailing
4261 WEST WHITE ROAD, OAKWOOD, GA 30566
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
110
Ownership type
A

2 citations on file for this inspection.

1910.219 C02 I

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $7566.00 · Current $4540.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  a) Five gallon filler line: On or about 7/16/2025, the employer exposed employees to caught-in hazards, in that the horizontal shaft on the five gallon filler line conveyor was not guarded and located approximately five feet and nine inches above the ground, within the seven-foot threshold requiring guarding.
Recent events (2)
  • — I (O) $4539.6
  • — Z (S) $7566

1910.305 G01 IV

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv).  a) Located in the filling area: On or about 7/16/2025, flexible cords were observed being used in place of fixed wiring to supply power to wall-mounted fans. The use of flexible cords for this application is prohibited.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348375353.