Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TOOTSIE ROLL MFG., LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TOOTSIE ROLL MFG., LLC in 7401 S. CICERO AVE., CHICAGO, IL 60629 (NAICS 311340). OSHA activity number 348393257.

Watch Tootsie Roll MFG., LLC — free Get an email when a new federal OSHA severe-injury report for Tootsie Roll MFG., LLC is published. One employer, no account, unsubscribe in one click.
Site address
7401 S. CICERO AVE.
City
CHICAGO
State
IL
ZIP
60629
Mailing
7401 S. CICERO AVE., CHICAGO, IL 60629
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311340
Employees
590
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 II

Serious Gravity 10 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $16550.00 · Current $8275.00 Reduced
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection.   a) On or about July 17, 2025, employees were exposed to hazardous energy, when the employer failed to ensure that periodic inspections of energy control procedures were properly documented, in which did not identify the machine or equipment involved, the date of the inspection, the names of authorized employees participating in the inspection, or the name of the individual who conducted the inspection, as required.
Recent events (2)
  • — I (S) $8275
  • — Z (S) $16550

1910.147 D

Serious Gravity 10 1 instance 30 exposed
Issued
Penalty
Initial $16550.00 · Current $8275.00 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)(6):  a) Tootsie Wrap Department - On or about July 17, 2025, an employee was exposed to machine hazards associated with moving parts when an employee sustained a laceration while clearing a jam at the overhead metal detector for the brown loop. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], Lockout/Tagout device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $8275
  • — Z (S) $16550

1910.212 A01

Serious Gravity 10 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Tootsie Wrap Dept: On or about July 17, 2025, Employee #1, a general laborer, was manually cleaning candy near the Asset #7301 Overhead metal detector WHD Midgee for the brown loop conveyor belt when the employee slipped and fell, coming into contact with exposed moving machine parts. As a result, employee #1 sustained a laceration to their right bicep,  and remained hospitalized.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348393257.