Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BEST QUALITY EXTERIORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BEST QUALITY EXTERIORS, INC. in S NORTHBANK PLACE LOT 19A-20H, PHILADELPHIA, PA 19125 (NAICS 238160). OSHA activity number 348406356.

Watch Best Quality Exteriors, INC. — free Get an email when a new federal OSHA severe-injury report for Best Quality Exteriors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
S NORTHBANK PLACE LOT 19A-20H
City
PHILADELPHIA
State
PA
ZIP
19125
Mailing
7322 MILNOR STREET, PHILADELPHIA, PA 19136
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.405 A02 II I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2412.00 · Current $2412.00
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:  a) Jobsite located at or near S Northbank Place, Lot 19A-20H Philadelphia, PA - On or about July 30, 2025, the employer did not ensure all flexible cords that were used for temporary wiring were not passed through doorways or other pinch points, thereby exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $2412

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2412.00 · Current $2412.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) Jobsite located at or near S Northbank Place, Lot 19A-20H Philadelphia, PA - On or about July 30, 2025, the employer did not ensure worn, or damaged flexible cord sets were removed from service.  Employees used flexible cord sets with external defects including but not limited to damaged wire insulation, thereby exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $2412

1926.453 B02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3972.00 · Current $3972.00
29 CFR 1926.453(b)(2)(v): 29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:  a) Jobsite located at or near S Northbank Place, Lot 19A-20H Philadelphia, PA - On or about July 30, 2025,  the employer did not ensure employees working in an aerial lift wore a personal fall arrest or travel restraint system.  Employees installed siding in an aerial lift without the use of fall protection, thereby exposing employees to fall hazards.
Recent events (1)
  • — Z (S) $3972

View BEST QUALITY EXTERIORS, INC.'s full OSHA safety record →