DANIELSON, CT —
OSHA Inspection: CDLS MOBILE REPAIR LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CDLS MOBILE REPAIR LLC in 915 NORTH MAIN STREET, DANIELSON, CT 06239 (NAICS 811111). OSHA activity number 348414137.
Where did this inspection happen?
- Establishment
- CDLS MOBILE REPAIR LLC
- Site address
- 915 NORTH MAIN STREET
- City
- DANIELSON
- State
- CT
- ZIP
- 06239
- Mailing
- 915 NORTH MAIN STREET, DANIELSON, CT 06239
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 14
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $3972.00 · Current $2383.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees were exposed to struck-by/caught in between hazards from an inadequate automotive lift inspection program: Service station/bay: On or about August 1, 2025, an automotive lift located in the service station/bay had not been subject to an inspection by a qualified person in the current year: Station/bay, Blue Rotary lift.
Recent events (2)
- — I (S) $2383.2
- — Z (S) $3972
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $2270.00 · Current $1362.00 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition. Mechanic shop/ Doorway entrance: On or about August 1, 2025, extension cords were laid on the floor of the mechanic shop and doorway entrance while employees regularly traverse to perform mechanical type work activities, exposing them to trip and fall hazards.
Recent events (2)
- — I (S) $1362
- — Z (S) $2270
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $3972.00 · Current $2383.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. Mechanic shop: On or about August 1, 2025, relocatable power taps (power strips) were series-connected (daisy-chained) to extension cords or other power strips not designed for its intended purpose was providing electrical power to various mechanic shop related equipment, lighting, air compressor, vehicle lift, 30 ton lift, and garage doors for employees to use, exposing them to electrical, stuck by, caught in between hazards.
Recent events (2)
- — I (S) $2383.2
- — Z (S) $3972
1910.303 B08 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was mounted. Mechanic shop/ Doorway entrance: On or about August 1, 2025, three junction boxes that were interconnected near the doorway, was not mounted and secured to the surface while energizing various mechanic shop related equipment, lighting, air compressor, vehicle lift, 30-ton lift, and garage doors that were being used by the employees to perform mechanical work exposing them to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 D02
- Issued
- Abate by
- Penalty
- Initial $3972.00 · Current $2383.00 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front: Mechanic shop: On or about August 1, 2025, employees were exposed to electrical hazards from the exposed live parts of a 240v electrical panel without a dead front installed that was routinely used by the employees.
Recent events (2)
- — I (S) $2383.2
- — Z (S) $3972
1910.305 G01 IV
- Issued
- Abate by
- Penalty
- Initial $3972.00 · Current $2383.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (D). Mechanic shop: On or about August 1, 2025, flexible cords were used for the following; A) Flexible cords (Extension cords) were used as a substitute for fixed or permanent wiring while energizing various mechanical shop related equipment, lighting, air compressor, vehicle lift, 30-ton lift, garage doors. B) Flexible cords (Extension cords) were run through a wall near the ceiling by the door way entrance while energizing various mechanic shop related equipment and lighting. C) Flexible cords (Extension cords) were run through a door way entrance to another room while energizing various mechanic shop related equipment and lighting. D) Flexible cords (Extension cords) were attached with staples and tie wraps to building surfaces while energizing various mechanical shop related equipment, lighting, air compressor, vehicle lift, 30-ton lift, garage doors.
Recent events (2)
- — I (S) $2383.2
- — Z (S) $3972
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Mechanic Shop/Doorway: On or about August 1, 2025, three junction boxes that were interconnected near the doorway, had exposed insulated wires from a cable without the proper devices and fittings for strain relief to prevent pulling while energizing various mechanic shop related equipment, lighting, air compressor, vehicle lift, 30-ton lift, and garage doors that were being used by the employees to perform mechanical work exposing them to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Mechanic Shop/Doorway: On or about August 1, 2025, portable fire extinguishers were not mounted and found on the ground against the wall inaccessible and subjecting employees to prolonged fire exposure and the byproducts of combustion.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811111)
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
MANASSAS, VA—2026-07-15
VAFMC LLC
NORFOLK, VA—2026-07-15
CITY OF NORFOLK DEPT OF GENERAL SERVICES DIVISION OF FLEET MANAGEMENT
ENOLA, PA—2026-07-15
ENOLA AUTO SALES
LYNCHBURG, TN—2026-07-14
MOORE COUNTY SCHOOLS - BUS GARAGE
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source