EL RENO, OK —
OSHA Inspection: DEXTER AXLE CO. LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DEXTER AXLE CO. LLC in 500 SE 27TH ST, EL RENO, OK 73036 (NAICS 336350). OSHA activity number 348427022.
Where did this inspection happen?
- Establishment
- DEXTER AXLE CO. LLC
- Site address
- 500 SE 27TH ST
- City
- EL RENO
- State
- OK
- ZIP
- 73036
- Mailing
- 500 SE 27TH ST, EL RENO, OK 73036
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336350
- Employees
- 144
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.107 B03
- Issued
- Abate by
- Penalty
- Initial $14188.00 · Current $8500.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(3): The floor surface of a spray booth and operator's working area, when combustible, was not covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues. On or about August 7, 2025, and at times prior thereto, at the Torflex paint booth, the floor surface within the spray booth was covered with a combustible material.
Recent events (2)
- — I (O) $8500
- — Z (S) $14188
1910.107 B09
- Issued
- Abate by
- Penalty
- Initial $14188.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction. On or about August 7, 2025, and at times prior thereto, at the Torflex paint booth, a clear space of at least three (3) feet was not maintained around all sides of the spray booth.
Recent events (2)
- — I (O) $0
- — Z (S) $14188
1910.107 G02
- Issued
- Abate by
- Penalty
- Initial $14188.00 · Current $8500.00 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. On or about August 7, 2025, and at times prior thereto, at the TorFlex paint booth, the walls of the spray booth were not kept free from the accumulation of deposits of combustible residue.
Recent events (2)
- — I (S) $8500
- — Z (S) $14188
More inspections in this industry (NAICS 336350)
CRAWFORDSVILLE, IN—2026-06-12
RAYBESTOS POWERTRAIN
FORT DEPOSIT, AL—2026-06-01
SEJONG ALABAMA, L.L.C.
STERLING HEIGHTS, MI—2026-05-29
FORD MOTOR COMPANY STERLING AXLE PLANT
MURRAY, KY—2026-05-28
69154 - DAE-IL USA INC
BELLOWS FALLS, VT—2026-05-21
SONNAX TRANSMISSION COMPANY
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source