WASHINGTON, DC —
OSHA Inspection: CGS ELECTRIC LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CGS ELECTRIC LLC in 3900 GEORGIA AVE, WASHINGTON, DC 20011 (NAICS 238210). OSHA activity number 348441064.
Where did this inspection happen?
- Establishment
- CGS ELECTRIC LLC
- Site address
- 3900 GEORGIA AVE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20011
- Mailing
- 6326 CLINTON WAY, CLINTON, MD 20735
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On or about August 15, 2025; Westside of site; employees working in a trench estimated to be 5 feet deep had no means of egress or exit available while carrying out their assigned duties during the conduit installation. This created a safety risk, as the lack of exits method such as a ladder could hinder quick evacuation in the event of an emergency or collapse. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3500
- — Z (S) $4965
1926.651 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(j)(2):Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) On or about August 15, 2025; Westside of site: the employer failed to position the spoil pile the necessary two feet away from the excavation site, thereby exposing employees to a significant risk of engulfment while they carried out their assigned tasks, such as the placement of conduit. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(k)(1):Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. a) On or about August 15, 2025; Westside of site: the employer failed to conduct daily inspections of both the work area and the trench, which are critical steps in ensuring worker safety. These inspections are essential to identify and correct potential hazards, such as the risk of cave-ins, which could lead to serious injuries or fatalities. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) On or about August 15, 2025; Westside of site: employees were actively engaged in the installation of conduits within an unguarded trench that was approximately 5 feet deep. During this process, they faced potential for a cave-in. Proper safety measures should have been in place to abate such hazards such as but not limited to the installation of a trench box. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238210)
PARKVILLE, MD—2026-07-15
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15
EDGE ELECTRICAL SYSTEMS, LLC
LAYTON, UT—2026-07-14
LYNN WOODWARD ELECTRIC LLC
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
ANNAPOLIS, MD—2026-07-14
J.M. MULLEN ELECTRICAL SERVICES, INC.
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348441064.