OSHA Inspection: HUGHES TRIM LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HUGHES TRIM LLC in 4450 EAGLE FALLS PLACE, TAMPA, FL 33619 (NAICS 238350). OSHA activity number 348445511.

Watch Hughes Trim LLC — free Get an email when a new federal OSHA severe-injury report for Hughes Trim LLC is published. One employer, no account, unsubscribe in one click.
Establishment
HUGHES TRIM LLC
Site address
4450 EAGLE FALLS PLACE
City
TAMPA
State
FL
ZIP
33619
Mailing
4450 EAGLE FALLS PLACE, TAMPA, FL 33619
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238350
Employees
51
Ownership type
A

8 citations on file for this inspection.

1910.178 L02 II

Serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $6621.00 · Current $6621.00
29 CFR  1910.178(l)(2)(ii):The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.  a) On or about August 15, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, employees were exposed to struck-by and crush-by hazards because forklift operators had not completed the required training program.
Recent events (2)
  • — C (S) $6621
  • — Z (S) $6621

1910.334 A02 I

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $5296.00 · Current $5296.00
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) On or about August 15, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, employees were exposed to a fire hazard due to the damaged electrical cord on an industrial fan. The cord exhibited visible damage to its outer jacket and insulation, and had not been subjected to the required pre?shift visual inspection
Recent events (2)
  • — C (S) $5296
  • — Z (S) $5296

1910.334 A02 II

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  a) On or about August 15, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, employees were exposed to a fire and electrical hazard because the cord for an industrial fan had visible damage and the fan was not removed from service.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $5296.00 · Current $5296.00
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) On or about August 15, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, the employer did not provide employees handling chemical products, such as wood stains, with effective information and training on hazardous chemicals in their work area.
Recent events (2)
  • — C (S) $5296
  • — Z (S) $5296

1910.134 C02 I

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(c)(2)(i):Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) On or about August 25, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, the employer did not provide employees who were permitted to use half-face respirators voluntarily with the information contained in Appendix D - Information for Employees Using Respirators When not Required Under Standard.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  a) On or about August 25, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, the employer did not provide a medical evaluation to employees who were permitted to use half-face respirators voluntarily.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) On or about August 15, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, employees were exposed to smoke, fire, and entrapment hazards because a portable fire extinguisher was not properly identified, making it difficult to locate in an emergency.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check:(a)   a) On or about August 15, 2025, at the warehouse located at 4450 Eagle Falls Place, Tampa, FL 33619, employees were exposed to smoke, fire, and entrapment hazards because a portable fire extinguisher had not received an up-to-date annual maintenance check.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348445511.