COLORADO SPRINGS, CO —
OSHA Inspection: GRIFFIN FAST LUBE COLORADO SPRINGS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GRIFFIN FAST LUBE COLORADO SPRINGS, LLC in 2310 S ACADEMY BLVD, COLORADO SPRINGS, CO 80916 (NAICS 811191). OSHA activity number 348459306.
Where did this inspection happen?
- Establishment
- GRIFFIN FAST LUBE COLORADO SPRINGS, LLC
- Site address
- 2310 S ACADEMY BLVD
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80916
- Mailing
- 1040 NORTH UNION AVE SUITE 320, FARMINGTON, UT 84025
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811191
- Employees
- 9
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.244 A02 III
- Issued
- Abate by
- Penalty
- Initial $11823.00 · Current $7094.00 Reduced
General-duty citation text
29 CFR 1910.244(a)(2)(iii):Loads were not cribbed, blocked or otherwise secured immediately after being raised with a jack. a) On or about August 22, 2025, and at times prior, the employer did not ensure loads were cribbed, blocked or otherwise secured after being raised with a Daytona floor jack when an employee was performing brake repairs on both the left and right side of a Dodge Ram Promaster van, requiring him to place portions of his body including his head under the van on both the left and right side. The left side of the van was raised with a Dayton floor jack and only the right side had a jack stand to secure the load.
Recent events (2)
- — I (S) $7093.8
- — Z (S) $11823
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $9457.00 · Current $5674.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). a) On or about August 22, 2025, and at times prior the employer did not ensure that inside the breaker panel in the saw area, that live parts of electrical equipment operating at 50 volts or more were guarded against accidental contact by use of approved cabinets or other forms of approved enclosures, there were open breaker sections inside the panel. b) On or about August 22, 2025, and at times prior, the employer did not ensure the electrical boxes coming from the electrical panel with electrical wires were covered to prevent accidental contact.
Recent events (2)
- — I (S) $5674.2
- — Z (S) $9457
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $7093.00 · Current $4256.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii). a) On or about August 22, 2025, the employer did not implement a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii) when employees worked with chemicals including but not limited to anti-freeze (Ready Fill 50/50 BTHOAT), O'Reilly Brake Parts Cleaner-Non-Chlorinated, Ceramic Extreme Brake Parts Lubricant, and Premium Windshield Washer Fluid, Mighty VS7 products including Brake Fluid, Battery product with hazards including but not limited to Compressed gas H280, Muta. 1B H340, Carc. 1A H350, Acute Tox. 4 (Oral) H302, Acute Tox. 4 , H332, Skin Irritant 2 H315, Eye Dam. 1 H318, STOT RE 2 H373, Flammable Liquid Category 3, Flammable aerosol Category 2 H223, Compressed gas H280, Acute toxicity (oral) Category 3 H301, Acute toxicity (dermal) Category 3 H311, Skin corrosion/irritation Category 2 H315, Serious eye damage/eye irritation Category 2A H319, Reproductive toxicity Category 2 H361, Narcosis H336
Recent events (2)
- — I (S) $4255.8
- — Z (S) $7093
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. a) On or about August 22, 2025, and at times prior the employer did not ensure that there was a safety data sheet in the workplace for each hazardous chemical which they use in that the employer could not locate a SDS onsite for any of the chemicals used including but not limited to anti-freeze (Ready Fill 50/50 BTHOAT), O'Reilly Brake Parts Cleaner-Non-Chlorinated, Ceramic Extreme Brake Parts Lubricant, and Premium Windshield Washer Fluid, Mighty VS7 products including Brake Fluid, Battery Cleaner with hazards including but not limited to Compressed gas H280, Muta. 1B H340, Carc. 1A H350, Acute Tox. 4 (Oral) H302, Acute Tox. 4 (Inhalation:dust,mist) H332, Skin Irrit. 2 H315, Eye Dam. 1 H318, STOT RE 2 H373, Flammable Liquid Category 3, Flammable aerosol Category 2 H223, Compressed gas H280, Acute toxicity (oral) Category 3 H301, Acute toxicity (dermal) Category 3 H311, Skin corrosion/irritation Category 2 H315, Serious eye damage/eye irritation Category 2A H319, Reproductive toxicity Category 2 H361, Narcosis H336.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area. a) On or about August 22, 2025, and at times prior the employer did not ensure employees were provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment. On or about August 22, 2025 and at times prior the employer did not assess the workplace to determine if hazards are present or likely to be present which necessitate the use of personal protective equipment when employees performed oil changes, brake replacements, battery replacements, changing sparkplugs, and performing other automotive maintenance tasks exposing employees to hazards including but not limited to lacerations, chemical exposure, chemical splashing in the eyes, hot liquids, and hot surfaces.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.133(a)(1):Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment. a) On or about August 22, 2025, and at times prior the employer did not ensure that protective eye equipment was used when an employee was performing brake repair and using an impact gun, exposing the employee to eye struck by and foreign objects.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GRIFFIN FAST LUBE COLORADO SPRINGS, LLC
PEYTON, CO—2017-06-14 00:00:00
GRIFFIN FAST LUBE COLORADO SPRINGS, LLC.
FOUNTAIN, CO—2017-03-21 00:00:00
GRIFFIN FAST LUBE COLORADO SPRINGS, LLC
View GRIFFIN FAST LUBE COLORADO SPRINGS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 811191)
FALCON, CO—2026-07-08
WALMART AUTO CARE CENTER
WYOMING, MI—2026-07-07
NR AUTOMOTIVE
WESTLAND, MI—2026-06-29
TAKE 5 OIL CHANGE 3820
CASTLE ROCK, WA—2026-06-24
WA317991795 - CASTLE ROCK AUTO CARE INC
SUNNYSIDE, WA—2026-06-22
WA317991753 - FIRST CHOICE LUBE & OIL LLC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source