EASTON, PA —
OSHA Inspection: TIOGA PIPE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TIOGA PIPE, INC. in 100 MORT DRIVE, EASTON, PA 18040 (NAICS 423510). OSHA activity number 348481680.
Where did this inspection happen?
- Establishment
- TIOGA PIPE, INC.
- Site address
- 100 MORT DRIVE
- City
- EASTON
- State
- PA
- ZIP
- 18040
- Mailing
- 2450 WHEATSHEAF LANE, PHILADELPHIA, PA 19137
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 35
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $5107.00 · Current $3830.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) 100 Mort Drive Easton, PA - On or about September 4, 2025 the employer did not implement a procedure for the hazardous control of all energy sources on the hydrostatic testing machines.
Recent events (2)
- — I (S) $3830.25
- — Z (S) $5107
1910.184 F05 I
- Issued
- Abate by
- Penalty
- Initial $3830.00 · Current $2873.00 Reduced
General-duty citation text
29 CFR 1910.184(f)(5)(i): Wire rope sling(s) that had ten or more randomly distributed broken wires in one rope lay, or five or more broken wires in one strand in one rope lay, were not immediately removed from service: a) 100 Mort Drive Easton, PA - On or about September 4, 2025 wire rope slings used to adjust the hydrostatic testing heads with the crane had broken wires which required removal from service.
Recent events (2)
- — I (S) $2872.5
- — Z (S) $3830
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $7661.00 · Current $5746.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation: a) 100 Mort Drive Easton, PA - On or about September 4, 2025 guarding was not provided to protect operators of the hydrostatic testing machine from potential contact with high pressure water in the event a seal fails.
Recent events (2)
- — I (S) $5745.75
- — Z (S) $7661
More inspections in this industry (NAICS 423510)
HAMMOND, IN—2026-07-07
JUPITER ALUMINUM CORPORATION
BETTENDORF, IA—2026-07-06
A09CS000011UWT9AAA - OLYMPIC STEEL, INC.
GREELEY, CO—2026-07-01
NORFOLK IRON & METAL COMPANY
OAKLAND, CA—2026-06-30
TAV HOLDINGS, INC.
HOUSTON, TX—2026-06-29
SEOJIN GLOBAL INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348481680.