Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTHERN ELITE REMODELING & ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTHERN ELITE REMODELING & ROOFING LLC in 1119 HAMRIC DRIVE WEST, ANNISTON, AL 36203 (NAICS 238160). OSHA activity number 348486655.

Watch Southern Elite Remodeling & Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Southern Elite Remodeling & Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
1119 HAMRIC DRIVE WEST
City
ANNISTON
State
AL
ZIP
36203
Mailing
301 S QUINTARD AVENUE, ANNISTON, AL 36201
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:  (a) On or about September 5, 2025, on the roof; employee(s) utilized impact drills without a personal fall arrest system in place while performing standing seam metal panel installation activities on the exterior of the residential roof at a height of 6 feet or more to the ground below.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.503 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:  (a) On or about September 5, 2025, on the roof; employee(s) utilized impact drills without receiving training on fall hazards prior to performing standing seam metal panel installation activities on the exterior of the residential roof at a height of 6 feet or more to the ground below.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) On or about September 5, 2025, on the roof; employee(s) utilized aluminum ladders to access and egress the roof without the ladder side rails extending at least 3 feet past the roof landing while performing standing seam metal panel installation activities on the exterior of the residential roof at a height of 6 feet or more to the ground below.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.1060 A

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1060(a):The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways:  (a) On or about September 5, 2025, on the roof; employee(s) utilized aluminum ladders to access and egress the roof without receiving ladder safety training prior to performing standing seam metal panel installation activities on the exterior of the residential roof at a height of 6 feet or more to the ground below.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348486655.