Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIVINE ENERGY SOLUTIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIVINE ENERGY SOLUTIONS, INC. in 493 WEST LOOKOUT AVE, HACKENSACK, NJ 07601 (NAICS 238220). OSHA activity number 348506569.

Watch Divine Energy Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Divine Energy Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
493 WEST LOOKOUT AVE
City
HACKENSACK
State
NJ
ZIP
07601
Mailing
200 RICHARDS AVENUE, DOVER, NJ 07801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
3
Ownership type
A

7 citations on file for this inspection.

1910.134 E01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $0.00 Reduced
29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:   a) 493 West lookout Ave: Employees were required to use an N95 respirator without being medical evaluated, on or about 9/16/25.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2837

1910.134 F01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(1):The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  a) 493 West Lookout Ave, Hackensack NJ: The  Employer did not ensure that employees using respirators were fit tested, on or about 9/16/25
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2837.00 · Current $2000.00 Reduced
29 CFR  1926.102(a)(1):The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   a) Right side of the residential home: Employees were exposed to eye injuries while spraying insolation without the use of eye and face protection, on or about 9/16/25.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2837

1926.152 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2837.00 · Current $2000.00 Reduced
29 CFR  1926.152(a)(1):Containers other than approved metal safety cans were used for the handling and use of flammable liquids in quantities greater than one gallon:  a) Inside a working box truck: Employees were utilizing an unapproved 5 gallon container with flammable liquids, on or about 9/16/25
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2837

1926.300 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3618.00 · Current $2000.00 Reduced
29 CFR  1926.300(b)(2):Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating, or moving parts of equipment exposed to contact by the employees or which otherwise created a hazard, were not guarded:  a) Box work truck: Employees were exposed to amputations hazards, while working approximately 2 inches from unguarded gears, on or about 9/16/25.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3618

1926.1053 B07

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $3618.00 · Current $2000.00 Reduced
29 CFR  1926.1053(b)(7): Ladders shall not be used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement. Slip-resistant feet shall not be used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery.  a) Right side of the residential home: Ladders were not secured or provided with good condition slip-resistant feet to prevent accidental displacement on slippery surfaces as required, on or about 9/16/25
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3618

1926.1053 B15

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $3618.00 · Current $2000.00 Reduced
29 CFR  1926.1053(b)(15): Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.  a) Front and right side of the residential home: Ladders were not inspected as required for visible defects, on or about 9/16/25 -
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3618

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348506569.