ROCHESTER, NY —
OSHA Inspection: GSP COMPONENTS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GSP COMPONENTS INC in 1190 BROOKS AVENUE, ROCHESTER, NY 14624 (NAICS 332721). OSHA activity number 348508037.
Where did this inspection happen?
- Establishment
- GSP COMPONENTS INC
- Site address
- 1190 BROOKS AVENUE
- City
- ROCHESTER
- State
- NY
- ZIP
- 14624
- Mailing
- 1190 BROOKS AVENUE, ROCHESTER, NY 14624
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 54
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and 29 CFR 1910.147(c)(4)(ii)(C):The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: On or about 09/16/2025 throughout the facility; where the documented energy control procedures did not have sufficiently specific procedures for removal by other than the employee who applied the device. The company's "Emergency Situation" procedures did not meet the requirements of 1910.147(e)(3) (attached below). 1910.147(e)(3): Lockout or tagout devices removal. Each lockout or tagout device shall be removed from each energy isolating device by the employee who applied the device. Exception to paragraph (e)(3): When the authorized employee who applied the lockout or tagout device is not available to remove it, that device may be removed under the direction of the employer, provided that specific procedures and training for such removal have been developed, documented and incorporated into the employer's energy control program. The employer shall demonstrate that the specific procedure provides equivalent safety to the removal of the device by the authorized employee who applied it. The specific procedure shall include at least the following elements: 1910.147(e)(3)(i) - Verfication by the employer that the authorized employee who applied the device is not at the facility; 1910.147(e)(3)(ii) - Making all reasonable efforts to contact the authorized employee to inform him/her that his/her lockout or tagout device has been removed; and 1910.147(e)(3)(iii) - Ensuring that the authorized employee has this knowledge before he/she resumes work at that facility. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (O) $0
1910.147 C05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(5)(ii):Lockout devices and tagout devices were utilized for other purposes than controlling energy: a) On or about 09/16/2025 in the CNC area between GT-01 and MIYANO-01; where a lock identified as "lockout lock" was used to secure an overhead bus duct switch in and "off" position after a piece of machinery was removed from the production floor. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 332721)
NEW ULM, MN—2026-06-24
111459 - SOUTHERN MINNESOTA TOOLING INC
MARION, NY—2026-06-12
MARION MACHINE MANUFACTURERS
ARCADE, NY—2026-05-26
DEVIN MFG., INC.
SANTA FE SPRINGS, CA—2026-05-21
LEFIELL MANUFACTURING
BELLINGHAM, MA—2026-04-30
GRAYCER SCREW PRODUCTS CO., INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348508037.