2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: GSP COMPONENTS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GSP COMPONENTS INC in 1190 BROOKS AVENUE, ROCHESTER, NY 14624 (NAICS 332721). OSHA activity number 348508037.

Watch GSP Components INC — free Get an email when a new federal OSHA severe-injury report for GSP Components INC is published. One employer, no account, unsubscribe in one click.
Establishment
GSP COMPONENTS INC
Site address
1190 BROOKS AVENUE
City
ROCHESTER
State
NY
ZIP
14624
Mailing
1190 BROOKS AVENUE, ROCHESTER, NY 14624
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332721
Employees
54
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II C

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and   29 CFR  1910.147(c)(4)(ii)(C):The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:  On or about 09/16/2025 throughout the facility; where the documented energy control procedures did not have sufficiently specific procedures for removal by other than the employee who applied the device. The company's "Emergency Situation" procedures did not meet the requirements of 1910.147(e)(3) (attached below).  1910.147(e)(3): Lockout or tagout devices removal. Each lockout or tagout device shall be removed from each energy isolating device by the employee who applied the device. Exception to paragraph (e)(3): When the authorized employee who applied the lockout or tagout device is not available to remove it, that device may be removed under the direction of the employer, provided that specific procedures and training for such removal have been developed, documented and incorporated into the employer's energy control program. The employer shall demonstrate that the specific procedure provides equivalent safety to the removal of the device by the authorized employee who applied it. The specific procedure shall include at least the following elements:     1910.147(e)(3)(i) - Verfication by the employer that the authorized employee who applied the device is not at the facility;     1910.147(e)(3)(ii) - Making all reasonable efforts to contact the authorized employee to inform him/her that his/her lockout or tagout device has been removed; and     1910.147(e)(3)(iii) - Ensuring that the authorized employee has this knowledge before he/she resumes work at that facility.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (O) $0

1910.147 C05 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(5)(ii):Lockout devices and tagout devices were utilized for other purposes than controlling energy:  a) On or about 09/16/2025 in the CNC area between GT-01 and MIYANO-01; where a lock identified as "lockout lock" was used to secure an overhead bus duct switch in and "off" position after a piece of machinery was removed from the production floor.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)