SAGINAW, TX —
OSHA Inspection: JM FIERRO CONSTRUCTION, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of JM FIERRO CONSTRUCTION, LLC in 1025 AYLESBURY RD, SAGINAW, TX 76179 (NAICS 238390). OSHA activity number 348508904.
Where did this inspection happen?
- Establishment
- JM FIERRO CONSTRUCTION, LLC
- Site address
- 1025 AYLESBURY RD
- City
- SAGINAW
- State
- TX
- ZIP
- 76179
- Mailing
- 2505 ROCK HAVEN ST, ARLINGTON, TX 76018
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 6
- Ownership type
- A
Citations
11 citations on file for this inspection.
1926.25 A
- Issued
- Abate by
- Penalty
- Initial $3547.00 · Current $2047.00 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: On or about September 2, 2025, and at times prior thereto, the employer did not ensure that housekeeping was being performed.
Recent events (2)
- — I (S) $2047
- — Z (S) $3547
1926.451 A06
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed and constructed by a qualified person: On or about September 2, 2025, and at times prior thereto, on a residential construction site, employees worked from scaffolds that were not designed and constructed by a qualified person while performing cornice work in the following instances (a-b): a) Single Pole Scaffold on the Westside of home was not designed and constructed by a qualified person; and b) Single Pole Scaffold on the Eastside of home was not designed and constructed by a qualified person.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about September 2, 2025, and at times prior thereto, on a residential construction site, employees worked from scaffolds that were not fully decked while performing cornice work in the following instances (a-b): a) Single Pole Scaffold on the Westside of home was not fully decked; and b) Single Pole Scaffold on the Eastside of home was not fully decked.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about September 2, 2025, and at times prior thereto, on a residential construction site, employees were working from scaffolds where the support poles were not equipped with base plates and/or mud sills in the following instances (a-c): a) Single Pole Scaffold poles on the Westside of home were not equipped with base plates and/or mud sills; b) Single Pole Scaffold poles on the Eastside of home were not equipped with base plates and/or mud sills; and c) Pump Jack Scaffold poles on the Eastside of home were not equipped with base plates and/or mud sills.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.451 C03
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: On or about September 2, 2025, and at times prior thereto, on a residential construction site, employees were working from supported scaffolds that were not plumb and braced in the following instances (a-c): a) Single Pole Scaffold on the Westside of home were not plumb and braced; b) Single Pole Scaffold on the Eastside of home were not plumb and braced; and c) Pump Jack Scaffold on the Eastside of home were not plumb and braced.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about September 2, 2025, and at times prior thereto, on the west side of a residential construction site, employee(s) worked from a scaffold without fall protection while performing cornice work.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.452 A04
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of single-pole scaffold: On or about September 2, 2025, and at times prior thereto, on a residential construction site, employees performed cornice work from single-pole scaffolds where cross-bracing was not installed in the following instances (a-b): a) Single Pole Scaffold on the Westside of home was not equipped with cross-bracing; and b) Single Pole Scaffold on the Eastside of home was not equipped with cross-bracing.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: On or about September 2, 2025, and at times prior thereto, on the east side of a residential construction site, employees were working from a pump jack scaffold that was not secured at the bottom.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about September 2, 2025, and at times prior thereto, employees were not provided training on the recognition of fall hazards while performing cornice insulation from scaffolds.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3465.00 Reduced
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: On or about September 2, 2025, and at times prior thereto, employees were not provided training on the recognition of hazards while erecting and using scaffolds.
Recent events (2)
- — I (S) $3465
- — Z (S) $4965
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $398.00 · Current $398.00
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: On or about September 2, 2025, and at times prior thereto, the employer did not develop and implement a safety and health programs to control and or eliminate hazardous conditions.
Recent events (2)
- — I (O) $398
- — Z (O) $398
More inspections in this industry (NAICS 238390)
WILMINGTON, NC—2026-07-09
161520 - LH ROOFING AND REMODELING LLC
ADDED FOR LEGACY MIGRATION, UK—2026-07-08
317744725 - WESTMARK CONSTRUCTION INC
BROOKLYN, NY—2026-07-08
SKYLINE RESTORATION INC.
LEBANON, PA—2026-07-01
STRUCTURAL RESTORATION SERVICES, INC
LEBANON, PA—2026-07-01
STRUCTURAL RESTORATION SERVICES, INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348508904.