On , OSHA opened a federal Agency safety inspection of DUNN ROADBUILDERS, LLC in 157 CHEVIS LEE RD., PETAL, MS 39465 (NAICS 237310). OSHA activity number 348577867.

Watch Dunn Roadbuilders, LLC — free Get an email when a new federal OSHA severe-injury report for Dunn Roadbuilders, LLC is published. One employer, no account, unsubscribe in one click.
Site address
157 CHEVIS LEE RD.
City
PETAL
State
MS
ZIP
39465
Mailing
411 WEST OAK ST, LAUREL, MS 39440
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
165
Ownership type
A

4 citations on file for this inspection.

1910.22 A03

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $12768.00 · Current $6697.00 Reduced
29 CFR  1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  (a) Conveyor belt - On or about October 30, 2025, the employer failed to keep the walkway clear of accumulation of excess gravel.
Recent events (2)
  • — I (S) $6697
  • — Z (S) $12768

1910.147 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $14895.00 · Current $14895.00
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) Conveyor main breaker panel - On or about October 30, 2025, the employer did not have specific procedures for shutting down the conveyor belt exposing employees to caught in hazards.
Recent events (2)
  • — I (S) $14895
  • — Z (S) $14895

1910.147 D03

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $16550.00 · Current $0.00 Reduced
29 CFR  1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).   (a) Conveyor main breaker panel - On or about October 30, 2025, the employer did not ensure that employees isolated and locked out conveyor belt system prior to servicing exposing employees to caught in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16550

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $16550.00 · Current $8790.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and   (a) Conveyor belt in rock yard - On or about October 30, 2025, the employer did not ensure that the incoming point of the conveyor belt at the drive drums were guarded prior to having employees work around the conveyor belt exposing employees to caught in hazards.
Recent events (2)
  • — I (S) $8790
  • — Z (S) $16550