Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAINIAO SUPPLY CHAIN US INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CAINIAO SUPPLY CHAIN US INC in 1000 HIGH ST, PERTH AMBOY, NJ 08861 (NAICS 492110). OSHA activity number 348604562.

Watch Cainiao Supply Chain US INC — free Get an email when a new federal OSHA severe-injury report for Cainiao Supply Chain US INC is published. One employer, no account, unsubscribe in one click.
Site address
1000 HIGH ST
City
PERTH AMBOY
State
NJ
ZIP
08861
Mailing
1000 HIGH ST, PERTH AMBOY, NJ 08861
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
492110
Employees
156
Ownership type
A

1 citation on file for this inspection.

1910.303 G02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $14895.00 · Current $14895.00
29 CFR  1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  A) Charging station #15 at 1000 High St, PERTH AMBOY, NJ 08861 - The employer did not guard the battery charging wire for the Raymond model 4460030 industrial truck at charging station #15 (64 volts) against accidental contact. This condition exposed employees to electric shock hazards.  Hazards observed on or about November 20, 2025.
Recent events (1)
  • — Z (S) $14895

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348604562.