OSHA Inspection: JOSE GUADALUPE VAZQUEZ HERNANDEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE GUADALUPE VAZQUEZ HERNANDEZ in 75 NIGHT FIRE LANE, DAWSONVILLE, GA 30534 (NAICS 238160). OSHA activity number 348614884.

Watch Jose Guadalupe Vazquez Hernandez — free Get an email when a new federal OSHA severe-injury report for Jose Guadalupe Vazquez Hernandez is published. One employer, no account, unsubscribe in one click.
Site address
75 NIGHT FIRE LANE
City
DAWSONVILLE
State
GA
ZIP
30534
Mailing
2349 EDGE COURT, DULUTH, GA 30096
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2270.00 · Current $1362.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) New single-family residential structure located at 75 Night Fire Lane, Dawsonville GA 300534, Roof: On or about 11/21/2025, the employer exposed employee to a fall hazard of approximately 12-feet 3-inches to the lower ground below, in that an adequate fall protection system was not utilized while working from the roofing area.
Recent events (2)
  • — I (S) $1362
  • — Z (S) $2270

1926.1053 B01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2270.00 · Current $0.00 Reduced
29 CFR  1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    a) New single-family residential structure located at 75 night Fire Lane, Dawsonville GA 300534, Ground level: On or about 11/21/2025, the employer exposed employee to a fall hazard of approximetly 12-feet 3-inches to the lower ground below, in that the portable extension ladder used to access the upper working area did not have a grasping device to assist employees in accessing the upper landing area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2270

1926.1053 B04

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed:  a) New single-family residential structure located at 75 night Fire Lane, Dawsonville GA 300534, Ground level: On or about 11/21/2025, the employer exposed employee to a fall hazard of approximately 12-feet 3-inches to the lower ground below, in that the portable extension ladder used to access the upper working area was not being used for the purpose it was designed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B16

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(16):Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.  a) New single-family residential structure located at 75 night Fire Lane, Dawsonville GA 300534, Ground level: On or about 11/21/2025, the employer exposed employee to a fall hazard of approximetly 12-feet 3-inches to the lower ground below, in that the portable extension ladder used to access the upper working had cut and dented rungs.