LORE CITY, OH —
OSHA Inspection: DUTCH BARN BUILDERS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DUTCH BARN BUILDERS, LLC in 18799 CADIZ ROAD, LORE CITY, OH 43755 (NAICS 321992). OSHA activity number 348626425.
Where did this inspection happen?
- Establishment
- DUTCH BARN BUILDERS, LLC
- Site address
- 18799 CADIZ ROAD
- City
- LORE CITY
- State
- OH
- ZIP
- 43755
- Mailing
- 18799 CADIZ ROAD, LORE CITY, OH 43755
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321992
- Employees
- 30
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C11
- Issued
- Penalty
- Initial $5628.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(11): Portable ladders used to gain access to an upper landing surface have side rails that extend at least 3 feet (0.9 m) above the upper landing surface. a) On or about December 4, 2025, the employer did not ensure the ladder's side rails extended 3 feet above the landing surface nor was the ladder secured with a grasping device for employees who accessed the roof of a storage shed in the assembly area. Employees utilized an extension ladder that was not extended beyond the roof's surface, exposing them to a fall height of more than 10 feet.
Recent events (3)
- — F (S) $0
- — C (S) $5628
- — Z (S) $5628
1910.28 B01 I
- Issued
- Penalty
- Initial $9268.00 · Current $7034.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following: a) On or about December 4, 2025, and at times prior, the employer did not ensure that employees installing roofing in the assembly area were protected from falling by providing a fall protection system. As a result, employees were exposed to a fall hazard of greater than 10 feet while building sheds in the shop.
Recent events (3)
- — F (S) $7034
- — C (S) $9268
- — Z (S) $9268
1910.30 A01
- Issued
- Penalty
- Initial $9268.00 · Current $7034.00 Reduced
General-duty citation text
29 CFR 1910.30(a)(1): (a) Fall hazards. (1) Before any employee is exposed to a fall hazard, the employer must provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart. a) On or about December 4, 2025, the employer failed to ensure that each employee exposed to fall hazards were trained on the hazards of falling and the procedures to minimize the hazards in the work area. As a result, employees were exposed to fall hazards greater than 10 feet while assembling barn sheds in the assembly area.
Recent events (3)
- — F (S) $7034
- — C (S) $9268
- — Z (S) $9268
1910.36 G01
- Issued
- Abate by
- Penalty
- Initial $3972.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.36(g)(1): The ceiling of an exit route must be at least seven feet six inches (2.3 m) high. Any projection from the ceiling must not reach a point less than six feet eight inches (2.0 m) from the floor. a) On or about December 4, 2025, the exit route traveling through the upstairs offices and/or conference room had a ceiling height of approximately 5 feet 11 inches. The condition impeded safe evacuation in the event of an emergency and exposed employees to a struck against hazard.
Recent events (3)
- — F (O) $0
- — C (S) $3972
- — Z (S) $3972
1910.305 G01 IV D
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv):Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: 29 CFR 1910.305(g)(1)(iv)(D): Where attached to building surfaces; a) On or about December 4, 2025, in the shed assembly area, a flexible cable was attached to the wall and was used to energize a retractable cord reel.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.27(a): Scaffolds. Scaffolds used in general industry must meet the requirements in 29 CFR part 1926, subpart L (Scaffolds). 29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. a) On or about December 4, 2025, the employer did not ensure the baker scaffolds used in the shed assembly area were inspected before each work shift and prior to use.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321992)
NAVASOTA, TX—2026-06-26
CHAMPION HOME BUILDERS, INC.
EAST MONTPELIER, VT—2026-06-18
HUNTINGTON HOMES, INC.
HUDSON, WI—2026-06-12
US LBM HOLDINGS, LLC
WAYNE, NE—2026-06-03
HERITAGE HOMES OF NEBRASKA INC
MOUNT JULIET, TN—2026-05-21
OLD TIMERS LOG HOMES & SUPPLY INC.
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348626425.