OSHA Inspection: WHITECO LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WHITECO LLC in 1625 BUTTS AVE, TOMAH, WI 54660 (NAICS 237130). OSHA activity number 348632266.

Watch Whiteco LLC — free Get an email when a new federal OSHA severe-injury report for Whiteco LLC is published. One employer, no account, unsubscribe in one click.
Establishment
WHITECO LLC
Site address
1625 BUTTS AVE
City
TOMAH
State
WI
ZIP
54660
Mailing
205 COOPER ST, BEAVER DAM, WI 53916
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
104
Ownership type
A

2 citations on file for this inspection.

1926.20 B01

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $14895.00 · Current $7448.00 Reduced

Hazardous substances C730

1926.20(b)(1):   The employer did not initiate and maintain such programs as may be necessary to comply with this part.  On or about December 5, 2026, programs were not maintained to ensure employees prevented exposure to carbon monoxide from a diesel powered heater and gasoline powered generator that were operating in an enclosed area.
Recent events (2)
  • — I (O) $7447.5
  • — Z (S) $14895

1926.55 A02

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $14895.00 · Current $14895.00

Hazardous substances C730

29 CFR  1926.55(a)(2): An employee(s) was exposed to substance(s) with a permissible exposure limit not preceded by (C) at concentrations above that specified in Table 1 of �1926.55 for that substance(s):  a) On or about December 5, 2026, at the worksite of 1625 Butts Ave Tomah, WI 54660, employee #1 was attempting to unthaw a frozen mixer with a portable diesel powered heater and a gas powered portable generator was exposed to carbon monoxide at a level of 206 ppm 8-hour Time Weighted Average, approximately 4.12 times the OSHA PEL of 50 PPM. This exposure was determined by Carboxyhemoglobin calculations over 480 minutes.  b) On or about December 5, 2026, at the worksite of 1625 Butts Ave Tomah, WI 54660, employee #2 was attempting to unthaw a frozen mixer with a portable diesel powered heater and a gas powered portable generator was exposed to carbon monoxide at a level of 133.7 ppm 8-hour Time Weighted Average, approximately 2.67 times the OSHA PEL of 50 PPM. This exposure was determined by Carboxyhemoglobin calculations over 480 minutes.
Recent events (2)
  • — I (S) $14895
  • — Z (S) $14895

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348632266.