PERTH AMBOY, NJ —
OSHA Inspection: WORLDPAK INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WORLDPAK INC. in 1037 STATE ST, PERTH AMBOY, NJ 08861 (NAICS 326111). OSHA activity number 348645516.
Where did this inspection happen?
- Establishment
- WORLDPAK INC.
- Site address
- 1037 STATE ST
- City
- PERTH AMBOY
- State
- NJ
- ZIP
- 08861
- Mailing
- 1037 STATE ST, PERTH AMBOY, NJ 08861
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326111
- Employees
- 17
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Penalty
- Initial $4256.00 · Current $2554.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A.) Worldpak Inc/1037 State Street, Perth Amboy, NJ 08861/The employer did not conduct periodic inspections of each energy control procedure at least annually to verify that the specific procedures for the Ro-An Polystar machines, were adequate and were being applied correctly. Condition noted on or about 12/16/2025.
Recent events (2)
- — I (S) $2553.6
- — Z (S) $4256
1910.147 C07 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a.)Worldpak Inc/1037 State Street, Perth Amboy, NJ, 08861/ The employer did not train employees to ensure that the purpose and functions of the energy control program were understood, while maintaining & cleaning the Ro-An Polystar machines. Condition noted on or about 12/16/2025.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $4256.00 · Current $2554.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: A) Worldpak Inc/1037 State Street, Perth Amboy, NJ 08861. The employer did not ensure that the Ro-An Polystar machines were guarded to protect against injuries. The machines did not have any guarding to prevent employees from accessing the zone of danger. Condition observed on or about 12/16/2025.
Recent events (2)
- — I (S) $2553.6
- — Z (S) $4256
More inspections in this industry (NAICS 326111)
TRAVERSE CITY, MI—2026-05-28
PLASCON INC
NEWARK, NJ—2026-05-21
NAP INDUSTRIES GROUP LLC
SAINT PAUL, MN—2026-05-19
111301 - REVOLUTIONS SUSTAINABLE SOLUTIONS LLC
SENOIA, GA—2026-04-29
WINPAK FILMS INC.
PISCATAWAY, NJ—2026-04-28
ALL AMERICAN POLY CORPORATION
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348645516.