Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WORLDPAK INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WORLDPAK INC. in 1037 STATE ST, PERTH AMBOY, NJ 08861 (NAICS 326111). OSHA activity number 348645516.

Watch Worldpak INC. — free Get an email when a new federal OSHA severe-injury report for Worldpak INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WORLDPAK INC.
Site address
1037 STATE ST
City
PERTH AMBOY
State
NJ
ZIP
08861
Mailing
1037 STATE ST, PERTH AMBOY, NJ 08861
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
326111
Employees
17
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 3 instances 3 exposed
Issued
Penalty
Initial $4256.00 · Current $2554.00 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  A.) Worldpak Inc/1037 State Street, Perth Amboy, NJ 08861/The employer did not conduct periodic inspections of each energy control procedure at least annually to verify that the specific procedures for the Ro-An Polystar machines, were adequate and were being applied correctly.  Condition noted on or about 12/16/2025.
Recent events (2)
  • — I (S) $2553.6
  • — Z (S) $4256

1910.147 C07 I

Serious Gravity 5 3 instances 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a.)Worldpak Inc/1037 State Street, Perth Amboy, NJ, 08861/ The employer did not train employees to ensure that the purpose and functions of the energy control program were understood, while maintaining & cleaning the Ro-An Polystar machines.  Condition noted on or about  12/16/2025.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $4256.00 · Current $2554.00 Reduced
29 CFR  1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  A) Worldpak Inc/1037 State Street, Perth Amboy, NJ 08861. The employer did not ensure that the Ro-An Polystar machines were guarded to protect against injuries.  The machines did not have any guarding to prevent employees from accessing the zone of danger.   Condition observed on or about 12/16/2025.
Recent events (2)
  • — I (S) $2553.6
  • — Z (S) $4256