HACKENSACK, NJ —
OSHA Inspection: K RESTORATION & ROOFING CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of K RESTORATION & ROOFING CORP. in 125 PROSPECT AVE, HACKENSACK, NJ 07601 (NAICS 238190). OSHA activity number 348650367.
Where did this inspection happen?
- Establishment
- K RESTORATION & ROOFING CORP.
- Site address
- 125 PROSPECT AVE
- City
- HACKENSACK
- State
- NJ
- ZIP
- 07601
- Mailing
- 211 E 123RD STREET, NEW YORK, NY 10035
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 D03 X
- Issued
- Abate by
- Penalty
- Initial $6620.00 · Current $4965.00 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle: (a): Exterior Suspended Scaffold South Side - Four employees working from the suspended scaffold were exposed to scaffold collapse hazards. The suspended scaffold beam tiebacks were installed at an angle, on or about December 11, 2025. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $4965
- — Z (S) $6620
1926.502 D15
- Issued
- Abate by
- Penalty
- Initial $8276.00 · Current $6207.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee (a): Exterior Suspended Scaffold South Side - Four employees were using personal fall arrest anchor points that were not independent of the suspended scaffold tieback anchors. The employees were exposed to fall hazards of approximately 30-60 feet when working on the suspended scaffold with improper anchor points, on or about December 11, 2025. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $6207
- — Z (S) $8276
More inspections in this industry (NAICS 238190)
BALDWINSVILLE, NY—2026-07-10
GD MAPSTONE, INC.
SAN ANTONIO, TX—2026-07-08
CAPITAL FOUNDATIONS, INC.
LITTLE FALLS, NJ—2026-07-07
ELITE CONTRACT GROUP
YAKIMA, WA—2026-07-07
WA317991947 - CASCADE WELDING SERVICES LLC
REDDING, CA—2026-07-07
JEFFERSON STATE BUILDERS INC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.