Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRIS SOLAR LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRIS SOLAR LLC in 1031 WHITE LEAF CIRCLE, CASTLE ROCK, CO 80108 (NAICS 238210). OSHA activity number 348664673.

Watch Pris Solar LLC — free Get an email when a new federal OSHA severe-injury report for Pris Solar LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PRIS SOLAR LLC
Site address
1031 WHITE LEAF CIRCLE
City
CASTLE ROCK
State
CO
ZIP
80108
Mailing
2060 W 10TH AVE APT 304, BROOMFIELD, CO 80020
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238210
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2838.00 · Current $1838.00 Reduced
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b):  a) On or about December 30, 2025, and at times prior the employer did not ensure that employees engaged in solar panel installation more than 6 feet above the lower level was protected by guardrail systems, safety net systems, or personal fall arrest systems
Recent events (2)
  • — I (S) $1838
  • — Z (S) $2838

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2838.00 · Current $1000.00 Reduced
29 CFR  1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a) On or about December 30, 2025, and at times prior, the employer did not ensure that a portable ladder used to access the 2nd story of the residential home to conduct solar panel installation was extended at least 3 feet above the landing surface or secured.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2838

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed.  a) On or about December 30, 2025, and at times prior, the employer did not ensure that an A-frame ladder used to access the 2nd story of the home from the first story roof was used for the purpose for which it was designed, in that it was not opened, but leaned up against the side of the house.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0