Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WAUSAU CONTAINER CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WAUSAU CONTAINER CORPORATION in 8000 HIGHLAND DR, WAUSAU, WI 54401 (NAICS 322212). OSHA activity number 348666041.

Watch Wausau Container Corporation — free Get an email when a new federal OSHA severe-injury report for Wausau Container Corporation is published. One employer, no account, unsubscribe in one click.
Site address
8000 HIGHLAND DR
City
WAUSAU
State
WI
ZIP
54401
Mailing
P.O. BOX 1285, WAUSAU, WI 54401
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
322212
Employees
75
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 75 exposed
Issued
Abate by
Penalty
Initial $9268.00 · Current $6488.00 Reduced
29 CFR  1910.147(c)(4)(ii):The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  (A) A specific statement of the intended use of the procedure;  (B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;  (C) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and  (D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.   On or about January 2, 2026 at an establishment located at 8000 Highland Dr, Wausau, Wisconsin, employees were required to perform servicing and maintenance machines for tasks such as, but not limited to, swapping of the die counter, dies, striping boards and blanking section pins. The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques, nor did the procedure identify all energy sources such as, but not limited to, gravitational, potential, hydraulic, thermal, and pneumatic to be isolated for the control of hazardous energy, and the means to enforce compliance.
Recent events (2)
  • — I (S) $6487.6
  • — Z (S) $9268

1910.147 D

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about January 2, 2026, at an establishment located at 8000 Highland Dr, Wausau, Wisconsin, employees were exposed to machine hazards associated with moving parts when they engaged in changeover activities on the Young Shin Industries Ltd. (Model: REVOTEC 106SB, Serial: YT-32-033005) flatbed die cutter machine.  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to enter the blanking section of the machine.  The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity exposing employees to gravitational energy.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F01

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(f)(1): Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed:  On or about December 23, 2025, at an establishment located at 8000 Highland Dr, Wausau, Wisconsin, employees making adjustments to an air lance on the Young Shin Industries Ltd. (Model: REVOTEC 106SB, Serial: YT-32-033005) flatbed die cutter were exposed to air embolism hazards when the machine was not guarded to prevent access to hazard areas.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348666041.