OSHA Inspection: ENGINEERED CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENGINEERED CONSTRUCTION LLC in 21075 CEDAR CREEK DRIVE, STRONGSVILLE, OH 44136 (NAICS 238110). OSHA activity number 348668443.

Watch Engineered Construction LLC — free Get an email when a new federal OSHA severe-injury report for Engineered Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
21075 CEDAR CREEK DRIVE
City
STRONGSVILLE
State
OH
ZIP
44136
Mailing
12412 YORK ROAD, NORTH ROYALTON, OH 44133
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238110
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.652 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $2979.00 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  On or about January 6, 2026, during the installation of water and sewer lines for the excavation of a residential home foundation at a worksite located at 21075 Cedar Creek Drive, Strongsville, Ohio, the employer failed to ensure an employee working inside a trench, with a varying depth of approximately 5.2 feet deep to approximately 9 feet deep were protected from cave-ins by an adequate protective system such as a properly designed benching system, trench shield, hydraulic shoring system, or other form of cave-in protection system.  The soil would have been classified as Type "B", cohesive soil.
Recent events (2)
  • — I (S) $2979
  • — Z (S) $4965

1926.651 C02

Repeat Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9930.00 · Current $5958.00 Reduced
29 CFR  1926.651(c)(2):Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  On or about January 6, 2026, during the installation of water and sewer lines for the excavation of a residential home foundation at a worksite located at 21075 Cedar Creek Drive, Strongsville, Ohio, the employer failed to ensure employees working inside a trench, with a varying depth of approximately 5.2 feet deep to approximately 9 feet deep and a length greater than 25 feet, were provided with a safe means of egress from the trench such as a stairway, ladder, and/or ramp.  Engineered Construction, LLC., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.651(c)(2) which was contained in OSHA inspection number 1518616, citation number 1, item number 2, and was affirmed as a final order on 4/13/2021, with respect to a workplace located at 7821 Hunting Lake Drive, Concord, Ohio.
Recent events (2)
  • — I (R) $5958
  • — Z (R) $9930

View ENGINEERED CONSTRUCTION LLC's full OSHA safety record →