Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DENNIS MENDOZA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DENNIS MENDOZA in 850 ELEVON PKWY, LAVON, TX 75166 (NAICS 238160). OSHA activity number 348676826.

Watch Dennis Mendoza — free Get an email when a new federal OSHA severe-injury report for Dennis Mendoza is published. One employer, no account, unsubscribe in one click.
Establishment
DENNIS MENDOZA
Site address
850 ELEVON PKWY
City
LAVON
State
TX
ZIP
75166
Mailing
910 GLYNN DR, GARLAND, TX 75040
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $3972.00
29 CFR  1926.501(b)(11):"Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.  On or about January 7, 2026 two employees were exposed to fall hazards while installing metal roof panels on a development amenities center with a steep pitch roof  at heights greater than six feet above lower levels without fall protection.
Recent events (1)
  • — Z (S) $3972

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $3972.00
29 CFR  1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  On or about January 7, 2026 employees installing metal roofing panels were exposed to falls by using a extension ladder  with side rails that did not extend at least 3 feet to access the roof landing approximately 12 feet above lower ground level.
Recent events (1)
  • — Z (S) $3972

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348676826.