Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GUIMAUTO CONSTRUCTION INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GUIMAUTO CONSTRUCTION INC in 2 PAGEWOOD OVAL, LITCHFIELD, NH 03052 (NAICS 236118). OSHA activity number 348717240.

Watch Guimauto Construction INC — free Get an email when a new federal OSHA severe-injury report for Guimauto Construction INC is published. One employer, no account, unsubscribe in one click.
Site address
2 PAGEWOOD OVAL
City
LITCHFIELD
State
NH
ZIP
03052
Mailing
10 BOLTON STREET, HUDSON, MA 01749
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

8 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2838.00 · Current $2100.00 Reduced
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:   Site- Employees working from a pump jack scaffold were not protected from a scaffold collapse hazard where the support poles for the scaffold were placed directly on the ground without mudsills or base plates, the ground was covered with ice and snow.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2838

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   Site- Employees working from pump jack scaffolds were not protected from scaffold collapse hazards where the support poles for the scaffolds did not have rigid triangular bracing at the bottom to prevent unintentional displacement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2838.00 · Current $0.00 Reduced
29 CFR  1926.451(f)(3):Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  Site- Employees working from two pump jack scaffolds were not protected from struck by, fall, and scaffold collapse hazards where a competent person did inspect the scaffolds prior to employees working from the scaffolds.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2838

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  Site- Employees erecting, dismantling, and working from two pump jack scaffold were not protected from struck by, fall, and scaffold collapse hazards where a competent person did not supervise the employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $3000.00 Reduced
29 CFR  1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:   Site- Employees working from two pump jack scaffolds were not protected from a fall of 13 feet where end rails and mid rails were not installed.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3972

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   Site- Employees working from two pump jack scaffolds were not protected from a fall of 13 feet where two Werner aluminum extension ladders were used horizontally as top rails for a guardrail and supporting building materials stacked on top of the ladders. The ladders are not designed to used as work benches supporting building materials or guardrails.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2838.00 · Current $2100.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   Site- Employees using an aluminum extension ladder to access a pump jack scaffold were not protected from a fall hazard where the ladder did not extend 3 feet above the landing surface.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2838

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $2838.00 · Current $2100.00 Reduced
29 CFR  1904.39(a)(2):The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye.  Site- On or about January 23, 2026 an employee sustained an injury requiring transport to the hospital by helicopter. The employer did not report the in-patient hospitalization to OSHA within 24 hours.
Recent events (2)
  • — I (O) $2100
  • — Z (O) $2838

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348717240.