OSHA Inspection: DEPARTMENT OF HOMELAND SECURITY (DHS)

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DEPARTMENT OF HOMELAND SECURITY (DHS) in 1664 WEEKSVILLE ROAD, ELIZABETH CITY, NC 27909 (NAICS 928110). OSHA activity number 348738386.

Watch Department OF Homeland Security (DHS) — free Get an email when a new federal OSHA severe-injury report for Department OF Homeland Security (DHS) is published. One employer, no account, unsubscribe in one click.
Site address
1664 WEEKSVILLE ROAD
City
ELIZABETH CITY
State
NC
ZIP
27909
Mailing
1664 WEEKSVILLE ROAD, ELIZABETH CITY, NC 27909
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
928110
Employees
125
Ownership type
D

2 citations on file for this inspection.

1910.101 A

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.101(a): The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that can be determined by visual or other inspections conducted as prescribed in the Hazardous Materials Regulations  On or about January 6, 2026, the employer did not ensure that a pressurized fire bottle was maintained in a safe condition. The pressurized fire bottle was outside of the required hydrostatic testing interval.  Employees were exposed to struck-by and impact hazards due to the sudden release of pressurized components.
Recent events (1)
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(7)(i):Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.  On or about January 6, 2026, the employer did not ensure that unused openings in electrical panel were effectively closed. Electrical panel box had a missing knockout on the bottom right side.  Employees were exposed to electrical hazards.