OIL CITY, PA —
OSHA Inspection: JOLLEY ROOFING AND CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOLLEY ROOFING AND CONSTRUCTION LLC in 394 SENECA ST., OIL CITY, PA 16301 (NAICS 238160). OSHA activity number 348756065.
Where did this inspection happen?
- Establishment
- JOLLEY ROOFING AND CONSTRUCTION LLC
- Site address
- 394 SENECA ST.
- City
- OIL CITY
- State
- PA
- ZIP
- 16301
- Mailing
- PO BOX 143, UTICA, PA 16362
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B10
- Issued
- Penalty
- Initial $3618.00 · Current $2800.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a.) Jolley Roofing and Construction LLC, 394 Seneca St. Oil City, PA 16301,Commercial Roof- on or about 02/19/2026 and times prior thereto: Employees were installing shingles on Pathways Adolescent Center building without any protection from fall hazards. Employees were observed working within feet of the edge of the roof and were exposed to fall hazards of approximately 16 feet to ground level. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2800
- — Z (S) $3618
1926.28 A
- Issued
- Abate by
- Penalty
- Initial $2837.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.28(a):The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions. a.) Jolley Roofing and Construction LLC, 394 Seneca St. Oil City, PA 16301,Commercial Roof- on or about 02/19/2026 and times prior thereto: employees were observed using a pneumatic driven nailer/stapler during roofing operations without eye protection. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1000
- — Z (S) $2837
1926.1053 B01
- Issued
- Penalty
- Initial $2412.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a.) Jolley Roofing and Construction LLC, 394 Seneca St. Oil City, PA 16301, Commercial Roof- on or about 02/19/2026 and times prior thereto: The blue extension ladder that was used by employees to access the roof was extended approximately 1 foot above the upper landing surface at approximately 16-feet above ground level. NO ABATEMENT CERTIFICATION OR DOCUMENATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2412
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: a.) Jolley Roofing and Construction LLC, 394 Seneca St. Oil City, PA 16301,Commercial Roof- on or about 02/19/2026 and times prior thereto: The employer did not have a safety and health program. The company was engaged in construction work which involved the installation of a roof. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348756065.