ROCHESTER, NY —
OSHA Inspection: DIAMOND PAPERBOX, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIAMOND PAPERBOX, LLC in 111 COMMERCE DRIVE, ROCHESTER, NY 14623 (NAICS 322212). OSHA activity number 348808866.
Where did this inspection happen?
- Establishment
- DIAMOND PAPERBOX, LLC
- Site address
- 111 COMMERCE DRIVE
- City
- ROCHESTER
- State
- NY
- ZIP
- 14623
- Mailing
- 111 COMMERCE DRIVE, ROCHESTER, NY 14623
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322212
- Employees
- 249
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $7236 · Current $5427 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout is used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 03/13/2026 throughout establishment; where employees perform servicing/maintenance on machines and equipment including, but not limited to: presses, bandsaws, die cutting, slitting and packaging machines, the employer has not conducted, at least annually, reviews of authorized employees performing "hands on" energy control procedures. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5427
- — Z (S) $7236
1910.335 A02 II
- Issued
- Abate by
- Penalty
- Initial $7236 · Current $5427 Reduced
General-duty citation text
29 CFR 1910.335(a)(2)(ii): When normally enclosed live parts were exposed for maintenance or repair, they were not guarded to protect unqualified persons from contact with the live parts: a) On or about 03/13/2026 in the pressroom; where an electrical panel on Press #14 was open exposing energized conductors and no barriers were used to prevent access to unqualified personnel. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5427
- — Z (S) $7236
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $813 · Current $610 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 03/13/2026 throughout establishment; where the energy control procedures did not include the type and magnitude of hazardous energy to be controlled while performing servicing/maintenance on machines and equipment. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $609.75
- — Z (O) $813
1910.147 C05 II B
- Issued
- Abate by
- Penalty
- Initial $813 · Current $610 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size: a) On or about 03/13/2026 throughout the establishment; where the locks used for controlling hazardous energy were not standardized within the facility. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $609.75
- — Z (O) $813
More inspections in this industry (NAICS 322212)
MINNEAPOLIS, MN—2026-07-08
111554 - GREAT NORTHERN CORPORATION
WOOSTER, OH—2026-07-07
WELCH PACKAGING
BUFFALO, NY—2026-06-30
ENTERPRISE FOLDING BOX COMPANY, INC.
DAYTON, OH—2026-06-10
DAYTON CORRUGATED PACKAGING CORP.
DALLAS, TX—2026-05-20
CORRCHOICE/PCA LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source