2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PAX SERVICES GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PAX SERVICES GROUP in ARMY RESERVE CENTER GARAGE BUILDING, PAGO PAGO, AS 96799 (NAICS 238160). OSHA activity number 348869223.

Watch PAX Services Group — free Get an email when a new federal OSHA severe-injury report for PAX Services Group is published. One employer, no account, unsubscribe in one click.
Establishment
PAX SERVICES GROUP
Site address
ARMY RESERVE CENTER GARAGE BUILDING
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
5171 CASA BELLA, SAN ANTONIO, TX 78269
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.502 F01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $11916 · Current $8341 Reduced
29 CFR  1926.502(f)(1): Warning lines were not erected around all sides of the roof work area:  Army Reserve Center, Garage Building: On or about April 9, 2026, employees were working inside a warning line system that was not erected around all sides of the roof work area.
Recent events (4)
  • — I (S) $8341.2
  • — I (S) $8341.2
  • — Z (S) $11916

1926.502 G01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.502(g)(1)(i): When control lines are used, they shall be erected not less than 6 feet (1.8 m) nor more than 25 feet (7.7 m) from the unprotected or leading edge, except when erecting precast concrete members.  Army Reserve Center, Garage Building: On or about April 9, 2026, employees were working inside a warning line system that was not erected at least 6 feet away from the unprotected side or leading edge.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.502 H01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.502(h)(1): The employer did not did not designate a competent person to monitor the safety of other employees and/or did not ensure that the safety monitor complied with the requirements listed in (h)(1)(i) through (h)(1)(v) of this section:  Army Reserve Center, Garage Building: On or about April 9, 2026, a safety line system was used as the fall protection method for employees conducting roofing work on the approximately 23ft roof, and there was not a designated competent person in place to monitor the employees.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348869223.