1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ULRICH FABRICATION INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ULRICH FABRICATION INC in 2120 FOURTH AVENUE, LAKEWOOD, NY 14750 (NAICS 332322). OSHA activity number 348884974.

Site address
2120 FOURTH AVENUE
City
LAKEWOOD
State
NY
ZIP
14750
Mailing
2120 FOURTH AVENUE, LAKEWOOD, NY 14750
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332322
Employees
35
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I C

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $6207 · Current $3500 Reduced
29 CFR  1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:  a) On or about 04/17/2026 throughout the establishment; where the annual review of authorized employees performing a lockout was last performed in 2022.   ABATEMENT CERTIFICATION REQUIRED  NOTE: Per 1910.147(c)(6)(i) the periodic inspections shall be conducted at least annually .
Recent events (2)
  • — I (S) $3500
  • — Z (S) $6207

1910.217 B08 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5276 · Current $2500 Reduced
29 CFR  1910.217(b)(8)(iii): Mechanical power press control(s) did not incorporate a type of drive motor starter that would disconnect the drive motor from the power source in event of control voltage or power source failure and require operation of the motor start button to restart the motor when voltage conditions are restored to normal:  a) On or about 04/17/2026 in the Paperline area: where the Kenco 8 Ton mechanical power press had an "on/off" switch which would permit the machine to automatically restart after an interruption of power if the switch was in the "on" position.  ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5276

1910.147 C04 II C

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:  a) On or about 04/17/2026 throughout the facility; where the employer's documented energy control procedures did not specifically identify the procedures which must be followed before removing a lockout lock by someone other than the employee who applied the lock. The employer's program contained vague statements such as: "efforts must be made to locate the lock owner" and "the safety manager may authorize the removal of the lock".  ABATEMENT CERTIFICATION REQUIRED    NOTE:  1910.147(e)(3) Lockout or tagout devices removal. Each lockout or tagout device shall be removed from each energy isolating device by the employee who applied the device. Exception to paragraph (e)(3): When the authorized employee who applied the lockout or tagout device is not available to remove it, that device may be removed under the direction of the employer, provided that specific procedures and training for such removal have been developed, documented and incorporated into the employer's energy control program. The employer shall demonstrate that the specific procedure provides equivalent safety to the removal of the device by the authorized employee who applied it. The specific procedure shall include at least the following elements:  1910.147(e)(3)(i) Verfication by the employer that the authorized employee who applied the device is not at the facility;  1910.147(e)(3)(ii) Making all reasonable efforts to contact the authorized employee to inform him/her that his/her lockout or tagout device has been removed; and  1910.147(e)(3)(iii) Ensuring that the authorized employee has this knowledge before he/she resumes work at that facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348884974.