105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025
OSHA's published Severe Injury Reports bulk file has not extended past 2025-10-31. We mirror the file as published; this banner auto-hides when OSHA resumes publication. For more recent records, browse accident investigations, Form 300/301 injuries, or OSHA inspections.

Search the archive

Search workplace incidents

Filter

Clear all
18,918 matching incidents · Page 1 of 757

Envelope Seal Insulation, Inc

NAICS238310 Event Struck by running powered equipment during maintenance, cleaning, testing Source Generators

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.
Amputations involving bone loss Thumb(s) and finger(s) Amputation
Read full record →

Smart Building Technologies - A Fidelity Company

NAICS238210 Event Fall to lower level resulting from exposure or contact unspecified Source Portable ladders and stairs unspecified

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
Surface, flesh wounds and burns, electrical injuries Hand(s), finger(s) unspecified Hospitalized
Read full record →

Burke Builders Inc

NAICS236220 Event Struck by running powered equipment n.e.c. Source Stationary saws table

An employee was cutting cabinet trim using a table saw when four fingers on his left hand were severed, resulting in hospitalization and amputation.
Amputations involving bone loss Other finger(s) n.e.c. Hospitalized Amputation
Read full record →

ABC Supply Company

NAICS238160 Event Fall to lower level from collapsing structure or equipment 6 to 30 feet Source Skylights or other existing roof openings

An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
Fractures Multiple body parts unspecified Hospitalized
Read full record →

Kasparian Underground LLC

NAICS237130 Event Exposure to electric arc Source Electrical wiring building or machine

An employee was terminating cables in a junction box. A loose ground wire came into contact with the bushing, causing a flash that burned the right side of the employee's face and his right hand.
Electrical burns any degree Head and extremities Hospitalized
Read full record →

Hobby Lobby Stores, Inc.

NAICS236220 Event Fall on same level due to slip or trip Source Other constructed surface

The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
Dislocations Ankle(s) Hospitalized
Read full record →

Foundation Steel, LLC

NAICS238120 Event Other fall to lower level unspecified Source Step ladders

An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
Closed trauma involving internal organs, major blood vessels Multiple internal chest locations Hospitalized
Read full record →

HB Fleming, Inc.

NAICS237990 Event Contact incidents unspecified Source Drilling machines, drill apparatus

A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.
Amputations, avulsions, enucleations unspecified Other finger(s) n.e.c. Amputation
Read full record →

Air-flo/Erwood Heating & Air Conditioning

NAICS238220 Event Fall on same level n.e.c. Source Other constructed surface

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.
Sprains, strains, tears unspecified Exterior and musculoskeletal structures of the neck Hospitalized
Read full record →

Cashless Tolling Constructors

NAICS237310 Event Other fall to lower level 6 to 30 feet Source Bridges, dams, locks

An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.
Fractures Multiple trunk locations Hospitalized
Read full record →

WADDELL CONCRETE INC.

NAICS238110 Event Other fall to lower level unspecified Source Structural elements n.e.c.

An employee was readjusting a safety hook to remove hardware from gang forms when his feet slipped. He fell to the ground, resulting in a broken left arm and wrist.
Fractures Wrist(s) and arm(s) n.e.c. Hospitalized
Read full record →

RG Professional Carpenter, Inc.

NAICS238130 Event Struck by other falling object n.e.c. Source Walls

The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
Fractures Pelvis Hospitalized
Read full record →

Bucket Enterprises LLC

NAICS238910 Event Pedestrian struck by forward-moving vehicle in road work zone Source Dump trucks

An employee was assisting the crew with patching and restoring a roadway after the installation of a sewer line. He was helping place and level the blacktop/backfill material over the trench area to bring the road surface back to proper grade. The employee was walking between a forward-moving dump truck and a dirt pile when his right foot was run over by the truck s wheel, causing him to fall. The employee sustained injury to his foot.
Traumatic injuries or exposures unspecified Foot (feet), toe(s) unspecified Hospitalized
Read full record →

Red Dot Corporation

NAICS238120 Event Struck by other falling object n.e.c. Source Beams and rails metal

An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
Bruises, contusions Thigh(s) Hospitalized
Read full record →

VILLAGER CONSTRUCTION, INC.

NAICS238910 Event Pedestrian struck by forward-moving vehicle in road work zone Source Roadway vehicle motorized, unspecified

An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.
Fractures Part of body unspecified Hospitalized
Read full record →

Abbott Electric Inc

NAICS238210 Event Collision with stationary object, nonroadway Source Hoists, lifts scissor, telescoping

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
Traumatic injuries or exposures unspecified Exterior and musculoskeletal structures of the back unspecified Hospitalized
Read full record →

UPSON COMPANY

NAICS238160 Event Fall to lower level from collapsing structure or equipment 6 to 30 feet Source Multipurpose ladders

An employee was standing on a multi-purpose ladder installing head flashing over a window. Their feet were approximately 6 feet off the ground and three rungs from the top. The employee lost their grip on the drill they were using and the ladder tipped over. The employee fell from the ladder to the ground, resulting in a fractured left wrist, bruised chest, and lacerations to their face and lip.
Fractures Wrist(s) Hospitalized
Read full record →

Zimmerman & Herr

NAICS238140 Event Caught or wedged between objects nonrunning Source Industrial vehicle, material hauling and transport powered, n.e.c.

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
Amputations involving bone loss Finger or thumb tip(s), nail(s) Amputation
Read full record →

Asher Enterprises, Inc.

NAICS238170 Event Fall to lower level from collapsing structure or equipment unspecified Source Portable ladders and stairs unspecified

An employee was on a ladder, taking measurements for a new gutter installation. The ladder slipped out from under him and both he and the ladder fell to the ground. He was hospitalized with seven broken ribs and a broken clavicle.
Fractures Trunk and other upper extremities Hospitalized
Read full record →

Corrigan Brothers Inc

NAICS238220 Event Struck by door, gate, window Source Doors, hatches vehicle and machine cabin

An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.
Amputations, avulsions, enucleations unspecified Finger or thumb tip(s), nail(s) Amputation
Read full record →

Viking Utility Construction

NAICS237130 Event Exposure to electric arc Source Power lines, transformers, convertors

An employee was using a bucket truck hoist to raise secondary aerial wiring. The wire made contact with the primary wire, causing an arc flash. The employee suffered burns to both hands and was hospitalized.
Electrical burns any degree Hand(s), finger(s) unspecified Hospitalized
Read full record →

Cornell & Company, Inc.

NAICS238120 Event Other fall to lower level 6 to 30 feet Source Trusses, girders, beams structurally attached

An employee was standing on the surface of a steel beam about two feet wide. He slipped and fell backward, landing on the concrete ground about 20 feet below. The employee sustained a broken pelvis.
Fractures Pelvis Hospitalized
Read full record →

Heavy Equipment Movers and Installation, LLC

NAICS238290 Event Caught, entangled in running powered equipment normal operation Source Other material and personnel handling machinery n.e.c.

An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.
Avulsions, enucleations without bone loss Thumb(s) Hospitalized
Read full record →

Anderson Columbia Co., Inc.

NAICS237310 Event Other fall to lower level 6 to 30 feet Source Sewers, drains, water pipes

An employee was cleaning out an inlet pipe in a stormwater structure. The employee stepped back, fell into the pipe, and landed on concrete 13 feet below, at the bottom of the structure. He suffered a broken back.
Fractures Exterior and musculoskeletal structures of the back unspecified Hospitalized
Read full record →

Simon Contractors of South Dakota, Inc.

NAICS237110 Event Struck by other falling object n.e.c. Source Other product testing, inspecting, and diagnostic machinery

An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
Fractures Leg(s) unspecified Hospitalized
Read full record →