Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 70,589Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

Rea Magnet Wire Company, Inc.

Caught in running equipment or machinery during regular operation · Amputations

Federal OSHA recorded a severe workplace injury at Rea Magnet Wire Company, Inc., 129 Soundview Road, GUILFORD, CONNECTICUT 06437 on , Amputations, affecting the fingertip(s).

Watch Rea Magnet Wire Company, Inc. for free Get an email when a new federal OSHA severe-injury report for Rea Magnet Wire Company, Inc. is published. One employer, no account, unsubscribe in one click.

An employee was setting up a three-stand mill machine. As he placed his right hand on the block, his left hand pressed the jog forward button instead of the tension off button, causing the block to rotate counterclockwise and amputate his right middle and ring fingertips. The jog button was unguarded at the time.

Hospitalized Amputation Fingertip(s) Milling machines