Federal OSHA recorded a severe workplace injury at Wieland Rolled Products North America, LLC, 305 Lewis and Clark Blvd, EAST ALTON, ILLINOIS 62024 on , Amputations, affecting the finger(s), fingernail(s), unspecified.

Watch Wieland Rolled Products North America, LLC for free Get an email when a new federal OSHA severe-injury report for Wieland Rolled Products North America, LLC is published. One employer, no account, unsubscribe in one click.

An employee was measuring the thickness of a brass strip as it was being fed into a press. A micrometer the employee was using was pulled into a 4-inch gap at the press opening, taking the employee's right hand with it. The employee's little finger was partially amputated.

Amputation Finger(s), fingernail(s), unspecified Presses, except printing, n.e.c.