Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 70,589Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

Honeywell Safety Products USA, Inc.

Caught in running equipment or machinery, n.e.c. · Amputations

Federal OSHA recorded a severe workplace injury at Honeywell Safety Products USA, Inc., 10 Thurber Boulevard, SMITHFIELD, RHODE ISLAND 02917 on , Amputations, affecting the finger(s), fingernail(s), unspecified.

Watch Honeywell Safety Products USA, Inc. for free Get an email when a new federal OSHA severe-injury report for Honeywell Safety Products USA, Inc. is published. One employer, no account, unsubscribe in one click.

At about 4:00 a.m. on June 26, 2020, an employee was setting up a newly installed ultrasonic welder. While he was adjusting the head of the equipment on the mount relative to the welding plate, a gap was created between the head of the equipment and the welding fixture. When the computer recognized that the machine was too far out of adjustment, the welding fixture recoiled back up, closing the gap on the employee's left index finger. The finger was partially amputated.

Amputation Finger(s), fingernail(s), unspecified Welding machinery