SMITHFIELD, RHODE ISLAND—
Honeywell Safety Products USA, Inc.
Caught in running equipment or machinery, n.e.c. · Amputations
Final narrative
At about 4:00 a.m. on June 26, 2020, an employee was setting up a newly installed ultrasonic welder. While he was adjusting the head of the equipment on the mount relative to the welding plate, a gap was created between the head of the equipment and the welding fixture. When the computer recognized that the machine was too far out of adjustment, the welding fixture recoiled back up, closing the gap on the employee's left index finger. The finger was partially amputated.
Similar incidents · Same event type
MIDLAND, TEXAS—
Scout Surface Solutions
Employees were assembling and testing a butterfly valve unit and actuator combo. When the unit was function tested with air, the valve gate closed on an employee's left thumb resulting in a fracture and laceration.
CHESTER, ILLINOIS—
Gilster-Mary Lee Corporation
An employee was doing a daily inspection of the sifter screen on a mixer when the mixer line activated. The armature for the screen struck the employee's right wrist. Their wrist was cut and their hand was fractured.
DALLAS, TEXAS—
Maxwell Paper Products Co
An employee was being trained on a machine when a roller came down on their hand, resulting in a fracture and laceration.
CONESTOGA, PENNSYLVANIA—
Turkey Hill LLC
An employee was doing a dry run during the setup of an ice cream machine. The machine indexed and the filler head amputated the employee's left middle finger above the last knuckle.
ERIE, PENNSYLVANIA—
Erie Strayer Company
An employee was on a 3-foot ladder guiding cable onto a spool during installation on an overhead door. As the control box was jogged, the employee's hand was caught between the cable and spool, resulting in a wrist and hand fracture.