Dexmet Corporation

Caught in running equipment or machinery during maintenance, cleaning · Amputations

Federal OSHA recorded a severe workplace injury at Dexmet Corporation, 22 Barnes Industrial Road South, WALLINGFORD, CONNECTICUT 06492 on , Amputations, affecting the finger(s), fingernail(s), n.e.c..

Watch Dexmet Corporation for free Get an email when a new federal OSHA severe-injury report for Dexmet Corporation is published. One employer, no account, unsubscribe in one click.

An employee was operating a mesh cutting machine. A piece of mesh was rolling out of the machine and started to coil onto itself rather than coming out as a flat section. The employee was working to straighten the material to prevent it from jamming the machine when the machine amputated their middle finger between the fingernail and knuckle.

Amputation Finger(s), fingernail(s), n.e.c. Metal, woodworking, and special material machinery, n.e.c.