Salem Tube, Inc.

Struck by running powered equipment during maintenance, cleaning, testing · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at Salem Tube, Inc., 485 Nickel Street, GREENVILLE, PENNSYLVANIA 16125 on , Amputations, avulsions, enucleations unspecified, affecting the other finger(s) n.e.c..

Watch Salem Tube, Inc. for free Get an email when a new federal OSHA severe-injury report for Salem Tube, Inc. is published. One employer, no account, unsubscribe in one click.

An employee was removing a tube that was stuck in a draw bench. The tube activated a sensor that dropped the inserter down, causing the tube to pull the employee's left little finger into the tube and the inserter wheels. The employee sustained a partial amputation and was hospitalized. The machine was not locked out at the time.

Hospitalized Amputation Other finger(s) n.e.c. Metal, woodworking, and special material machinery unspecified

View Salem Tube, Inc.'s full OSHA safety record →