Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31

Glanbia Nutritionals

Struck by running powered equipment during maintenance, cleaning, testing · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at Glanbia Nutritionals, 236 Washington St S, TWIN FALLS, IDAHO 83301 on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).

Watch Glanbia Nutritionals — free Get an email when a new federal OSHA severe-injury report for Glanbia Nutritionals is published. One employer, no account, unsubscribe in one click.

An employee was changing an O-ring on a pneumatic valve. The employee had placed the valve on his work cart and was applying air to open the valve and access the O-ring. After changing the O-ring, the valve closed on his fingertip, crushing it. He was taken to the hospital, where he received an amputation.

Amputation Finger or thumb tip(s), nail(s) Valves, nozzles