Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DELTA PARTS COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DELTA PARTS COMPANY in 847 W. MOUND STREET, COLUMBUS, OH 43223 (NAICS 000000). OSHA activity number 103171898.

Watch Delta Parts Company — free Get an email when a new federal OSHA severe-injury report for Delta Parts Company is published. One employer, no account, unsubscribe in one click.
Establishment
DELTA PARTS COMPANY
Site address
847 W. MOUND STREET
City
COLUMBUS
State
OH
ZIP
43223
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3714
Employees
6
Ownership type
A

21 citations on file for this inspection.

5(a)(1)

Serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $120.00 · Current $65.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
%%
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that:
On July 17, 1987, an employee pouring polyurethane bushings was exposed
to tuluene-2,-diisocyanate at a concentration of 0.04 ppm for a duration
of 26 minutes which is 2 times the ceiling standard of 0.02 ppm as
stated on the Cyanamid Material Safety Data Sheet (MSDS) for Cyanaprene
A-85 QM Urethane which contains toluene diisocyanate (TDI).
Also, this same exposure of 260 ug/m3 (0.26 mg/m3) for a duration of 26
minutes is 1.86 times the ten-minutes ceiling value of 140 ug/n3
recommended by the National Institute of Occupational Safety and Health
(NIOSH) in the 1978 publication entilted:  "Criteria for a Recommended
Standard... Occupational Exposure of Diisocyanates. "
Feasible administrative or engineering controls were not implemented to
reduce employee exposure. General methods of control applicable in these
circumstances include, but are not limited to the following:
1) Improved exhausting of vapor from the interior of the curing oven.
2) Modification of the design of the pouring ladles, by installation of
local exhaust ventilation or other devices to minimize the release of
vapor while the liquid is being poured. This approach may also
include the use of handles or spouts on the ladles to increase the
distance between the operators breathing zone and the point of vapor
release.
Recent events (2)
  • — I (S) $65.00
  • — Z (S) $120.00

1910.133 A01

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $120.00
Recent events (2)
  • — I (O)
  • — Z (S) $120.00

1910.133 A06

Serious 1 instance 1 exposed
Issued
Abate by

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.1200 F04 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by

1910.1200 F04 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by

1910.132 A

Serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $90.00 · Current $45.00 Reduced
Recent events (2)
  • — I (S) $45.00
  • — Z (S) $90.00

1910.134 A02

Serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $120.00 · Current $65.00 Reduced

Hazardous substances 9010

Recent events (2)
  • — I (S) $65.00
  • — Z (S) $120.00

1910.1000 C

Serious 1 instance 1 exposed
Issued
Abate by

1910.1000 E

Serious 1 instance 1 exposed
Issued
Abate by

Hazardous substances 9010

1903.2 A01

Other-than-serious 1 instance 6 exposed
Issued
Abate by

1910.94 A03 IA

Other-than-serious 1 instance 6 exposed
Issued
Abate by

1910.94 A03 IC

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.94 A04 IB

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.94 A04 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.151 C

Other-than-serious 1 instance 3 exposed
Issued
Abate by

1910.212 A05

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.212 B

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.212 A04

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.215 B09

Other-than-serious 1 instance 1 exposed
Issued
Abate by

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
Abate by

KGC, INC.

LIPPERT

PROVIA

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103171898.