Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ZUMBRO CONSTRUCTION, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ZUMBRO CONSTRUCTION, INC. in 10605 HAMMOCKS BLVD. - BLDG. #6, MIAMI, FL 33196 (NAICS 000000). OSHA activity number 106108939.

Watch Zumbro Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Zumbro Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10605 HAMMOCKS BLVD. - BLDG. #6
City
MIAMI
State
FL
ZIP
33196
Mailing
542 NE 10 AVENUE, FT. LAUDERDALE, FL 33313
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1751
Employees
9
Ownership type
A
Industry flags
Construction safety.

2 citations on file for this inspection.

5(a)(1)

Serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $280.00 · Current $280.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) On June 10, 1988 at the Hammocks Blvd. site, wooden roof trusses
being erected were not adequately braced to prevent a truss collapse,
exposing employee(s) to the hazards of being struck by, or falling
from collapsing trusses:
The following deficiences were noted:
1) Number of lateral braces were insufficient.
2) The lateral braces were not lapped a minimum of two (2) trusses each.
3) Lateral braces were not continuous for the entire length of the
building.
4) The first truss (end) were not braced securely (scabs were used).
5) No diagonal braces were used.
6) Web and bottom chord bracing were insufficient in amount.
7) Diagonal braces were not used, at the top chord, or Web, nor at the
bottom chord end bays.
8) Timber used for bracing was not minimum 2x4.
9) Nails used were not 16 Penny double headed.
10) Long laterals were not installed and short erection braces removed
immediately when possible.
Among other methods one feasible and acceptable method of abating these
hazards is to install trusses in accordance with the requirements of the
Truss Plate Institute which are contained in BWT-76 "Bracing Wood
Trusses".

1926.550 A09

Serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $200.00 · Current $200.00

View ZUMBRO CONSTRUCTION, INC.'s full OSHA safety record →