DUTCH HARBOR, AK —
OSHA Inspection: ROYAL ALEUTIAN SEAFOODS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROYAL ALEUTIAN SEAFOODS INC in MOORED AT EAST PT LOOP RD, DUTCH HARBOR, AK 99692 (NAICS 000000). OSHA activity number 107292930.
Where did this inspection happen?
- Establishment
- ROYAL ALEUTIAN SEAFOODS INC
- Site address
- MOORED AT EAST PT LOOP RD
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- P.O. BOX 920128, DUTCH HARBOR, AK 99692
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 65
- Ownership type
- A
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $490.00 · Current $245.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) P/B Royal Aleutian: Employees in the upper blast freezer, starboard side, had occasion to use a wall mounted duplex outlet that had a broken receptacle. This condition subjected the employees to the possibility of contacting energized electrical circuits, resulting in shock, burns, and/or electrocution. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the receptacle. b) P/B Royal Aleutian: Employees in the upper blast freezer, starboard side, had occasion to use shop built, gray 50 foot extension cord which was not equipped with a grounded male plug. This condition subjected the employees to the possibility of becoming a path to ground, resulting in shock, burns, and/or electrocution. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the male plug. c) P/B Royal Aleutian: Employees on the forward top deck had occasion to walk on the flexible power supply cable laying on the deck. Approximately 20 feet of flexible power cable was not enclosed in conduit and other required fittings. Cable supplied power for the hydraulic pump motor oin the plywood box. This condition subjected employees to the possibility of walking on energized wires resulting in shock, burns, or electrocution. Among other methods, one feasible and acceptable abatement method to correct this hazard is to wire the equipment to meet the National Electrical Code or Institute of Electrical and Electronics Engineers Standards. d) P/B Royal Aleution: Employees in the ice house, top deck, had occasion to work near or use the incandescent light fixtures that did not have the shielded wire secured in the strain relief fitting in the junction boxes. e) P/B Royal Aleution: Employees in the upper blast freezer, starboard side, had occasion to work near or use Dayton hacksaw that did not have the insulated wire jacket secured in the strain relief fitting in the box. Among other methods, one feasible and acceptable abatement method to correct this hazard is to wire the equipment to meet the National Electrical Code or Institute of Electrical and Electronics Engineers Standard. f) P/B Royal Aleution: Employees in the box up area had occasion to use a 4-inch junction box (type with knock-outs, designed to be enclosed in a wall) with a 100-volt duplex outlet, attached to a shop built drop cord. This condition subjected the employees to the possibility of touching the wet, defective junction box, resulting in shock, burns, and/or electrocution. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the 4-inch junction box with a portable weatherproof outlet box.
Recent events (2)
- — I (S) $245.00
- — Z (S) $490.00
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $490.00 · Current $245.00 Reduced
Recent events (2)
- — I (S) $245.00
- — Z (S) $490.00
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $560.00 · Current $280.00 Reduced
Recent events (2)
- — I (S) $280.00
- — Z (S) $560.00
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $560.00 · Current $280.00 Reduced
Recent events (2)
- — I (S) $280.00
- — Z (S) $560.00
1910.219 B01
- Issued
- Abate by
- Penalty
- Initial $350.00 · Current $175.00 Reduced
Recent events (2)
- — I (S) $175.00
- — Z (S) $350.00
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $420.00 · Current $210.00 Reduced
Recent events (2)
- — I (S) $210.00
- — Z (S) $420.00
1910.219 E03 I
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.219 I02
- Issued
- Abate by
- Penalty
- Initial $560.00 · Current $280.00 Reduced
Recent events (2)
- — I (S) $280.00
- — Z (S) $560.00
1910.243 C03
- Issued
- Abate by
- Penalty
- Initial $420.00 · Current $210.00 Reduced
Recent events (2)
- — I (S) $210.00
- — Z (S) $420.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $980.00 · Current $490.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) P/B Royal Aleutian: Employees in the box up area had occasion to use a shop built drop cord with a 4-inch junction box which was wired so as to reverse the polarity. This condition subjected the employees to the possibility of becoming a path to ground, resulting in shock, burns, and/or electrocution. Among other methods, one feasible and acceptable method to correct this hazard is to wire the duplex receptacle to meet the National Electric Code or Institute of Engineers and Electronic Engineers Standards. Royal Aleutian Seafoods was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent standard 29 CFR 1910.304(a)(2) which was contained in OSHA Inspection Number 107100117, Citation Number 1, Item Number 1, issued on 03/20/89.
Recent events (2)
- — I (R) $490.00
- — Z (R) $980.00
1910.157 E02
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
1918.11 A
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
1918.12 A
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
1918.74 A02
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
More inspections at ROYAL ALEUTIAN SEAFOODS INC
DUTCH HARBOR, AK—2004-01-30 00:00:00
ROYAL ALEUTIAN SEAFOODS INC
DUTCH HARBOR, AK—2004-01-28 00:00:00
ROYAL ALEUTIAN SEAFOODS INC
DUTCH HARBOR, AK—2004-01-28 00:00:00
ROYAL ALEUTIAN SEAFOODS INC
DUTCH HARBOR, AK—2003-02-01 00:00:00
ROYAL ALEUTIAN SEAFOODS INC
DUTCH HARBOR, AK—2003-02-01 00:00:00
ROYAL ALEUTIAN SEAFOODS INC
View ROYAL ALEUTIAN SEAFOODS INC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in AK
ANCHORAGE, AK—2026-07-10 00:00:00
AK, INC
ANCHORAGE, AK—2026-07-08 00:00:00
ONE STOP SERVICES
ANCHORAGE, AK—2026-07-08 00:00:00
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08 00:00:00
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07 00:00:00
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107292930.