Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ROYAL ALEUTIAN SEAFOODS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROYAL ALEUTIAN SEAFOODS INC in MOORED AT EAST PT LOOP RD, DUTCH HARBOR, AK 99692 (NAICS 000000). OSHA activity number 107292930.

Watch Royal Aleutian Seafoods INC — free Get an email when a new federal OSHA severe-injury report for Royal Aleutian Seafoods INC is published. One employer, no account, unsubscribe in one click.
Site address
MOORED AT EAST PT LOOP RD
City
DUTCH HARBOR
State
AK
ZIP
99692
Mailing
P.O. BOX 920128, DUTCH HARBOR, AK 99692
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2092
Employees
65
Ownership type
A

14 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 6 instances 39 exposed
Issued
Abate by
Penalty
Initial $490.00 · Current $245.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) P/B Royal Aleutian: Employees in the upper blast freezer, starboard
side, had occasion to use a wall mounted duplex outlet that had a
broken receptacle. This condition subjected the employees to the
possibility of contacting energized electrical circuits, resulting
in shock, burns, and/or electrocution.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to replace the receptacle.
b) P/B Royal Aleutian: Employees in the upper blast freezer, starboard
side, had occasion to use shop built, gray 50 foot extension cord
which was not equipped with a grounded male plug. This condition
subjected the employees to the possibility of becoming a path to
ground, resulting in shock, burns, and/or electrocution.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to replace the male plug.
c) P/B Royal Aleutian: Employees on the forward top deck had occasion
to walk on the flexible power supply cable laying on the deck.
Approximately 20 feet of flexible power cable was not enclosed in
conduit and other required fittings. Cable supplied power for the
hydraulic pump motor oin the plywood box. This condition subjected
employees to the possibility of walking on energized wires resulting
in shock, burns, or electrocution.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to wire the equipment to meet the National
Electrical Code or Institute of Electrical and Electronics Engineers
Standards.
d) P/B Royal Aleution: Employees in the ice house, top deck, had
occasion to work near or use the incandescent light fixtures that
did not have the shielded wire secured in the strain relief fitting
in the junction boxes.
e) P/B Royal Aleution: Employees in the upper blast freezer, starboard
side, had occasion to work near or use Dayton hacksaw that did not
have the insulated wire jacket secured in the strain relief fitting
in the box.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to wire the equipment to meet the National
Electrical Code or Institute of Electrical and Electronics Engineers
Standard.
f) P/B Royal Aleution: Employees in the box up area had occasion to use
a 4-inch junction box (type with knock-outs, designed to be enclosed
in a wall) with a 100-volt duplex outlet, attached to a shop built
drop cord. This condition subjected the employees to the possibility
of touching the wet, defective junction box, resulting in shock,
burns, and/or electrocution.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to replace the 4-inch junction box with a
portable weatherproof outlet box.
Recent events (2)
  • — I (S) $245.00
  • — Z (S) $490.00

1910.23 C01

Serious Gravity 07 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $490.00 · Current $245.00 Reduced
Recent events (2)
  • — I (S) $245.00
  • — Z (S) $490.00

1910.147 C04 I

Serious Gravity 08 1 instance 65 exposed
Issued
Abate by
Penalty
Initial $560.00 · Current $280.00 Reduced
Recent events (2)
  • — I (S) $280.00
  • — Z (S) $560.00

1910.212 A01

Serious Gravity 08 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $560.00 · Current $280.00 Reduced
Recent events (2)
  • — I (S) $280.00
  • — Z (S) $560.00

1910.219 B01

Serious Gravity 05 5 instances 1 exposed
Issued
Abate by
Penalty
Initial $350.00 · Current $175.00 Reduced
Recent events (2)
  • — I (S) $175.00
  • — Z (S) $350.00

1910.219 D01

Serious Gravity 06 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $420.00 · Current $210.00 Reduced
Recent events (2)
  • — I (S) $210.00
  • — Z (S) $420.00

1910.219 E03 I

Serious Gravity 06 1 instance 5 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.219 I02

Serious Gravity 08 1 instance 38 exposed
Issued
Abate by
Penalty
Initial $560.00 · Current $280.00 Reduced
Recent events (2)
  • — I (S) $280.00
  • — Z (S) $560.00

1910.243 C03

Serious Gravity 06 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $420.00 · Current $210.00 Reduced
Recent events (2)
  • — I (S) $210.00
  • — Z (S) $420.00

5(a)(1)

Repeat Gravity 07 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $980.00 · Current $490.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) P/B Royal Aleutian: Employees in the box up area had occasion to use
a shop built drop cord with a 4-inch junction box which was wired so
as to reverse the polarity. This condition subjected the employees to
the possibility of becoming a path to ground, resulting in shock,
burns, and/or electrocution.
Among other methods, one feasible and acceptable method to correct this
hazard is to wire the duplex receptacle to meet the National Electric
Code or Institute of Engineers and Electronic Engineers Standards.
Royal Aleutian Seafoods was previously cited for a violation of this
Occupational Safety and Health Standard or its equivalent standard 29
CFR 1910.304(a)(2) which was contained in OSHA Inspection Number
107100117, Citation Number 1, Item Number 1, issued on 03/20/89.
Recent events (2)
  • — I (R) $490.00
  • — Z (R) $980.00

1910.157 E02

Other-than-serious Gravity 03 5 instances 65 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

1918.11 A

Other-than-serious Gravity 03 1 instance 65 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

1918.12 A

Other-than-serious Gravity 03 2 instances 9 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

1918.74 A02

Other-than-serious Gravity 02 2 instances 9 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

View ROYAL ALEUTIAN SEAFOODS INC's full OSHA safety record →

KGC, INC.

AK, INC

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107292930.