BOHEMIA, NY —
OSHA Inspection: PREFERRED PLUMBING & HEATING
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PREFERRED PLUMBING & HEATING in 105 OROVILLE DRIVE, BOHEMIA, NY 11751 (NAICS 000000). OSHA activity number 107353062.
Where did this inspection happen?
- Establishment
- PREFERRED PLUMBING & HEATING
- Site address
- 105 OROVILLE DRIVE
- City
- BOHEMIA
- State
- NY
- ZIP
- 11751
- Mailing
- 10 BEECH STREET, ISLIP, NY 11751
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 1
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $600.00 · Current $600.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970. The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards associated with working with pipe threading pipe threading machines: (a) At the Worksite - Employee operated a Rigid 300 pipe threading machine activated by a toggle switch that would not automatically shut the machine off in case the operator was caught by the rotating pipe; on or about 6/25/92. ABATEMENT NOTES: Among other methods, one feasible method to reduce this hazard is to establish and enforce adequate safe operating procedures. Procedures such as those stipulated in Amrican Nationfal Standard for Portable Pipe Threading Machines (ANSI B208.1-1982). Elements essential to an acceptable safe operating procedure include at a minimum: 1. Installation of a momentary contact device (deadman foot switch) to control power input to the machine. This device would automatically stop the machine and the rotating pipe if the operator's foot was removed from the foot switch for any reason. 2. Provide training and education to the machine operators concerning all the appopriate procedures for the safe oper- ation and use of this type of machinery.
More inspections at PREFERRED PLUMBING & HEATING
SOLDOTNA, AK—2002-10-03 00:00:00
PREFERRED PLUMBING & HEATING
Garden City, NY—1983-11-03 00:00:00
PREFERRED PLUMBING & HEATING
Ronkonkoma, NY—1983-10-28 00:00:00
PREFERRED PLUMBING & HEATING
East Farmingdale, NY—1983-02-23 00:00:00
PREFERRED PLUMBING & HEATING
Northport, NY—1980-05-13 00:00:00
PREFERRED PLUMBING & HEATING
View PREFERRED PLUMBING & HEATING's full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107353062.