SOUTH BOSTON, MA —
OSHA Inspection: DREW ELECTRIC COMPANY, INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DREW ELECTRIC COMPANY, INCORPORATED in SUMMER STREET-MANHOLE #9292, SOUTH BOSTON, MA 02127 (NAICS 000000). OSHA activity number 107448003.
Where did this inspection happen?
- Establishment
- DREW ELECTRIC COMPANY, INCORPORATED
- Site address
- SUMMER STREET-MANHOLE #9292
- City
- SOUTH BOSTON
- State
- MA
- ZIP
- 02127
- Mailing
- 384 NEPONSET AVENUE, DORCHESTER, MA 02122
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1731
- Employees
- 2
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $810.00 · Current $410.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, working conditions and recognized hazards of possibly becoming overcome by toxic gas, oxygen deficient atmosphere, and carbon monoxide, while performing work duties from points located within manholes, shafts, and tunnels: Jobsite: Manhole #9293, Summer Street entrance to tunnel: Drew Electrical Co., Inc., employees entered a manhole and tunnel without following a confined space entry program procedure. Employees were exposed to the hazard of being asphyxiated due to the possiblelack of oxygen at their work locations, or being overcome by carbon monoxide or other contaminants. Among other methods, one feasible and acceptable abatement method to correct this hazard is to establish and enforce an adequate confined space entry procedure such as that stipulated by NIOSH Criteria Document Publication No. 80-106, December, 1979, which would include providing telephone or other signal communication(s) between stand by personnel and the employees in the confined space, training and providing instructions of the hazards and routine safety procedures/precautions of carbon monoxide, oxygen deficient atmospheres, and to other gasses associated with their working environment; and other aspectsof NIOSH Publication #80-106.
Recent events (2)
- — I (S) $410.00
- — Z (S) $810.00
1926.956 B01
- Issued
- Abate by
- Penalty
- Initial $810.00 · Current $630.00 Reduced
Recent events (2)
- — I (S) $630.00
- — Z (S) $810.00
More inspections at DREW ELECTRIC COMPANY, INCORPORATED
BOSTON, MA—1996-10-30 00:00:00
DREW ELECTRIC COMPANY, INCORPORATED
View DREW ELECTRIC COMPANY, INCORPORATED's full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in MA
WESTFORD, MA—2026-07-17 00:00:00
M&M CONSTRUCTION SERVICES CORP
ATTLEBORO, MA—2026-07-16 00:00:00
R M PACELLA INC
LYNN, MA—2026-07-16 00:00:00
A.M.B. IRON LLC
NEWTON, MA—2026-07-16 00:00:00
A&S CARPENTRY, INC.
BELLINGHAM, MA—2026-07-16 00:00:00
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 107448003.