SAIPAN, MP —
OSHA Inspection: ENVIRONMENTAL CHEMICAL CORPORATION
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ENVIRONMENTAL CHEMICAL CORPORATION in TANAPAG PCB PROJECT, TANAPAG, SAIPAN, MP 96950 (NAICS 000000). OSHA activity number 110528551.
Where did this inspection happen?
- Establishment
- ENVIRONMENTAL CHEMICAL CORPORATION
- Site address
- TANAPAG PCB PROJECT, TANAPAG
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- 1240 BAYSHORE HIGHWAY, BURLINGAME, CA 94010
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8744
- Employees
- 9
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $4500.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were accidentally exposed to the hazard of fine dust at high temperatures: a)The ECC Standard Operating Procedure (SOP) which described the full safety precautions to be followed before workers were allowed to open the ESP hatch on the Indirect Thermal Desorption (ITD) precipitator was inadequate in that: The SOP did not address or require the use of the air lance prior to opening the precipitator hatch to ensure that there had not been clogging and/or backup of dust in the precipitator. The SOP did not require visual observation at the soil conditioner interface opening to determine if concentration or backup of dust remained in the precipitator. One feasible and acceptable abatement method, among others, to correct this hazard is: Develop a comprehensive SOP that fully describes safety precautions to be followed before opening the ESP hatch including but not limited to: 1.a requirement to operate the air lance before opening the ESP hatch; 2.a requirement that employees use visual observation prior to hatch opening to ensure that there is no residual concentration of dust in the precipitator;
Recent events (2)
- — I (S) $4500.00
- — Z (S) $4500.00
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $4500.00
Recent events (2)
- — I (S) $4500.00
- — Z (S) $4500.00
More inspections at ENVIRONMENTAL CHEMICAL CORPORATION
CAMP LEJEUNE, NC—2020-11-18 00:00:00
ENVIRONMENTAL CHEMICAL CORPORATION
REDDING, CA—2018-12-06 00:00:00
ENVIRONMENTAL CHEMICAL CORPORATION
KITTERY, ME—2012-12-06 00:00:00
ENVIRONMENTAL CHEMICAL CORPORATION
JACKSONVILLE, FL—2010-07-02 00:00:00
ENVIRONMENTAL CHEMICAL CORPORATION
SAIPAN, MP—2002-09-03 00:00:00
ENVIRONMENTAL CHEMICAL CORPORATION
View ENVIRONMENTAL CHEMICAL CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in MP
SAIPAN, MP—2025-05-15
PARAGON CORP.
SAIPAN, MP—2025-05-14
WINZY CORPORATION
SAIPAN, MP—2025-05-14
HONG YE RENTAL & CONSTRUCTION, LTD.
SAIPAN, MP—2025-05-14
GU LI QIANG
SAIPAN, MP—2025-05-14
GENESIS ENTERPRISES, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110528551.