HANOVER, PA —
OSHA Inspection: STAMBAUGH METAL, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STAMBAUGH METAL, INCORPORATED in 802 HIGH STREET, HANOVER, PA 17331 (NAICS 332813). OSHA activity number 112900212.
Where did this inspection happen?
- Establishment
- STAMBAUGH METAL, INCORPORATED
- Site address
- 802 HIGH STREET
- City
- HANOVER
- State
- PA
- ZIP
- 17331
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 332813
- SIC code (legacy)
- 3471
- Employees
- 60
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $340.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burn injuries from the potential dust explosion hazard that could have resulted from, or been exacerbated by the dust collection system being located inside the building and having explosive dust travel through the air moving-device: (a)Prepolish Area - Employees polished steel engine guards on polishing machines provided with a dust collection system that was located inside the building and had the dust passing through the air-moving system, on or about August 4, 2003. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THESE HAZARDS INCLUDES, FOLLOWING NFPA 654, STANDARD FOR THE PREVENTION OF FIRE AND DUST EXPLOSIONS FROM THE MANUFACTURING, PROCESSING AND HANDLING OF COMBUSTIBLE PARTICULATE SOLIDS, 1997 EDITION, INCLUDING, BUT NOT LIMITED TO, LOCATING THE DUST-COLLECTION SYSTEM OUTSIDE OF THE BUILDING AND REDESIGNING THE VENTILATION SYSTEM TO REMOVE THE DUST BEFORE ENTERING THE AIR HANDLING DEVICE. VERIFICATION REQUIRED
Recent events (2)
- — I (S) $340.00
- — Z (S) $525.00
1910.212 A05
- Issued
- Abate by
- Penalty
- Initial $1225.00 · Current $795.00 Reduced
Recent events (2)
- — I (S) $795.00
- — Z (S) $1225.00
More inspections at STAMBAUGH METAL, INCORPORATED
HANOVER, PA—2012-04-03 00:00:00
STAMBAUGH METAL, INCORPORATED
HANOVER, PA—2003-03-20 00:00:00
STAMBAUGH METAL, INCORPORATED
HANOVER, PA—1999-04-26 00:00:00
STAMBAUGH METAL, INCORPORATED
HANOVER, PA—1996-04-03 00:00:00
STAMBAUGH METAL, INCORPORATED
HANOVER, PA—1995-06-01 00:00:00
STAMBAUGH METAL, INCORPORATED
View STAMBAUGH METAL, INCORPORATED's full OSHA safety record →
More inspections in this industry (NAICS 332813)
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WICHITA, KS—2026-07-15
PREMIER PROCESSING LLC
WARREN, MI—2026-07-14
AJAX METAL PROCESSING, INC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
WARSAW, IN—2026-07-08
SURFACE ENHANCEMENTS
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 112900212.