LYNBROOK, NY —
OSHA Inspection: BIANCO PLUMBING & HEATING, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of BIANCO PLUMBING & HEATING, INC. in 8 FREER STREET, LYNBROOK, NY 11563 (NAICS 000000). OSHA activity number 300137940.
Where did this inspection happen?
- Establishment
- BIANCO PLUMBING & HEATING, INC.
- Site address
- 8 FREER STREET
- City
- LYNBROOK
- State
- NY
- ZIP
- 11563
- Mailing
- 196 SERPENTINE LANE, ISLANDIA, NY 11787
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 6
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $375.00 · Current $375.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being pulled into and crushed by the rotating parts of a pipe threading machine: a)Senior Care Center- Employee Was operating a Rigid 300 pipe threading machine (serial number 788588) which was activated by a toggle switch that would not automatically shut the machine off if its operator was inadvertently caught up in its rotating parts. On or about 04/13/98. ABATEMENT NOTES: Among other methods, one feasible method to reduce this hazard is to establish and enforce adequate safe operating procedures. Procedures such as those stipulated in the Ridgid 300 Power Drive Pipe Threading Machine Operator's Manual. Elements essential to an acceptable safe operating procedure include at a minimum: 1.Installation and use of a momentary contact device (deadman foot switch) to control power input to the machine. This device would automatically stop the machine and the rotating pipe if the operator's foot was removed from the foot switch for any reason. 2.Provide training and education to the machine operators concerning all the appropriate procedure for the safe operation and use of this type of machinery, including the use of a foot switch.
More inspections at BIANCO PLUMBING & HEATING, INC.
L'ANSE, MI—2007-11-13 00:00:00
BIANCO PLUMBING & HEATING INC
View BIANCO PLUMBING & HEATING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NY
MAYVILLE, NY—2026-07-16 00:00:00
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16 00:00:00
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16 00:00:00
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15 00:00:00
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15 00:00:00
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300137940.