OSHA Inspection: NORTHERN ILLINOIS STEEL ERECTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NORTHERN ILLINOIS STEEL ERECTORS, INC. in ALLIED LOCKE, CORREGIDOR ROAD, DIXON, IL 61021 (NAICS 000000). OSHA activity number 300587342.

Watch Northern Illinois Steel Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Northern Illinois Steel Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ALLIED LOCKE, CORREGIDOR ROAD
City
DIXON
State
IL
ZIP
61021
Mailing
102 SANDRA AVE., MENDOTA, IL 61342
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1791
Employees
7
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $525.00 · Current $368.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
a place of employment which was free from recognized hazards that were
likely to cause death
or serious physical harm to employees. Employees were exposed to falling
while on steel beams
and columns that were not adequately braced in accordance with the
American National
Standards Institute's Standard for Steel Erection - Safety Requirements,
1989 edition, section
11.1.9.
On or about September 8, 1997. The steel structure was not adequately
braced in all
directions by the use of sufficent number of cables, stiffener beams, or
other methods.
Only one beam attached to the adjacent structure that was held by a 3/8
inch screw was
used to provide lateral stability to the newly erected structure.
Feasible abatement methods would include one of more of the following:
1) the installation of a bracing bay in the first erected bay, or
2)the use cables attached to secure members of the adjacent foundation or
structure
(not vehicles or aerial lifts), or
3)the use of stiffener beams that provided bracing in the diagonal
direction to the
column and horizontal beam.
NO CERTIFICATION OR DOCUMENTATION REQUIRED FOR THIS ITEM