YORKVILLE, NY —
OSHA Inspection: YORKVILLE BRAKE SERVICE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YORKVILLE BRAKE SERVICE, INC. in 701 ORISKANY BLVD., YORKVILLE, NY 13495 (NAICS 000000). OSHA activity number 300631074.
Where did this inspection happen?
- Establishment
- YORKVILLE BRAKE SERVICE, INC.
- Site address
- 701 ORISKANY BLVD.
- City
- YORKVILLE
- State
- NY
- ZIP
- 13495
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7539
- Employees
- 5
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a crushing hazard created by the sudden and unpredictable descent of vehicles elevated by automotive lifts: a)Bay 1, on or about 9/10/98: VBM Challenger Plus alignment lift, Serial #260056 had one of the locking devices tied down, making it inoperative, and no inspections were conducted of the lift, exposing employees to being struck by the vehicle should the lift fail. b)Bay 2, on or about 9/10/98: Weaver twin piston hydraulic lift had hydraulic leaks, no locking devices and no inspections were conducted of the lift, exposing employees to being struck by the vehicle should the lift fail. c)Bay 3, on or about 9/10/98: Weaver single piston hydraulic lift had no locking devices and no inspections were conducted of the lift, exposing employees to being struck by the vehicle should the lift fail. Among other methods, several feasible and acceptable methods to correct these hazards are to: 1.Install and/or repair mechanical locking devices. 2.Repair hydraulic leaks. 3.Establish a periodic inspection procedure as recommended by the manufacturer to ensure the safe operation of the lift. 4.Instruct all employees in the safe use and operation of the automotive lifts and their safety devices and ensure their routine use. Abatement documentation must be submitted for these items.
1910.22 B01
- Issued
- Abate by
1910.23 A09
- Issued
- Abate by
1910.212 A03 II
- Issued
- Abate by
1910.215 A02
- Issued
- Abate by
1910.219 D01
- Issued
- Abate by
1910.219 E03 I
- Issued
- Abate by
1910.1200 E01
- Issued
- Abate by
1910.1200 G08
- Issued
- Abate by
1910.1200 H01
- Issued
- Abate by
1910.305 A02 IIIF
- Issued
- Abate by
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300631074.