ALBUQUERQUE, NM —
OSHA Inspection: BRIGIDO'S BODY SHOP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BRIGIDO'S BODY SHOP in 2325 2ND ST. SW, ALBUQUERQUE, NM 87104 (NAICS 000000). OSHA activity number 303400865.
Where did this inspection happen?
- Establishment
- BRIGIDO'S BODY SHOP
- Site address
- 2325 2ND ST. SW
- City
- ALBUQUERQUE
- State
- NM
- ZIP
- 87104
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5015
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
90005 A
- Issued
- Abate by
- Penalty
- Initial $600.00 · Current $600.00
General-duty citation text
11 NMAC 5.2.9 Section 50-9-5(A), NMSA 1978 (New Mexico Occupational Health and Safety Act): Every employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees. PVC schedule 40 pipe was being used to distribute compressed air throughout the building. The use of PVC pipe for the distribution of compressed air has been prohibited by: American National Standards Institute/American Society of Mechanical Engineers Standards B31.8-1986, Gas Transmission and Distribution Piping Systems Standard, Sections 842.32, 842.43 and 849.52 American Society for Testing Materials D1785-86, Standard Specifications for Polyvinyl Chloride Plastic Pipe, Schedules 40, 80 and 120; and D2513-86a, Standard Specification for Thermoplastic Gas Pressure Piping Systems. Acceptable, and feasible means of abatement include, removing the PVC pipe and replacing with an approved type(some ABS materials, cast iron, etc.) or enclosing the pipe with an enclosure that is of sufficient strength to provide protection for the existing PVC pipe. Date Corrected Describe Corrective Action :
1910.134 C01
- Issued
- Abate by
1910.157 C01
- Issued
- Abate by
1910.253 B04 III
- Issued
- Abate by
1910.305 B02
- Issued
- Abate by
1910.305 J01 I
- Issued
- Abate by
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in NM
RIO RANCHO, NM—2026-07-15 00:00:00
PROFESSIONAL STUCCO & SERVICES INC.
RIO RANCHO, NM—2026-07-15 00:00:00
AAA ROOFING COMPANY
ALBUQUERQUE, NM—2026-07-09 00:00:00
HANK'S DESIGN HOUSE
LAS CRUCES, NM—2026-07-06 00:00:00
U-HAUL COMPANY OF SOUTHERN NEW MEXICO
HOBBS, NM—2026-07-01 00:00:00
FAMILY DOLLAR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303400865.